1Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Kasr El-Aini Street, Cairo, ET-11562, Egypt; Department of Chemistry, School of Life and Medical Sciences, University of Hertfordshire Hosted By Global Academic Foundation, New Capital, Garden City, Cairo, R5 New, Egypt.
Abstract:
Conventional miniaturized immunosensors featuring a single working electrode are often time-consuming due to the lengthy immunoassay procedures they require. Additionally, they necessitate background correction of the voltammetric signal. To overcome these challenges, a multichannel electrochemical immunosensor with six working electrodes has been developed. This innovative design enables the simultaneous analysis of six antigen solutions using the standard addition calibration protocol for precise background correction. This multichannel sensor has been used for cardiac troponin I (cTnI) determination in human serum using multiwall carbon nanotubes/carboxylate-functionalized polyaniline/gold nanoparticles working electrodes to ensure efficient electron transfer and immobilize cTnI antibodies. The immunoassay was optimized to employ a low concentration of cTnI antibody on a preactivated immunosensor, enabling a rapid assay completed within 45 min. The current signals in differential pulse voltammetry mode have been measured from the six electrodes at two different times. This enabled the plot of standard addition calibration for background correction with high reproducibility (RSD% = 2.64 %) in a dynamic range of 0.05-0.5 ng/mL cTnI antigen and detection limit of 0.02 ng/mL. Reliable quantification of cTnI in spiked and retained serum samples was obtained by the proposed electrode and compared favourably to chemiluminescent immunoassay. The proposed multi-electrode chip is not only inexpensive and simple to fabricate using photoresist etching but also allows efficient electrode switching through a homemade printed-circuit-board controller for practicality. This chip has been compared favourably to other reported electrochemical sensors, and it shows a feasible and reproducible approach for point-of-care diagnostics.
More Related Videos
10:12A Sensitive and Specific Quantitation Method for Determination of Serum Cardiac Myosin Binding Protein-C by Electrochemiluminescence Immunoassay
Published on: August 8, 2013
07:40Impact of High-intensity Interval Exercise and Moderate-Intensity Continuous Exercise on the Cardiac Troponin T Level at an Early Stage of Training
Published on: October 10, 2019
Related Concept Videos
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...