Related Experiment Video
Updated: Sep 13, 2025

Method for Simultaneous fMRI/EEG Data Collection during a Focused Attention Suggestion for Differential Thermal Sensation
Published on: January 5, 2014
An experimental study on the detection mechanism of 2-CEES using SAW sensors under various temperature conditions
Hee-Chan Jang1, Sanjeeb Lama1, Jaeyoung Heo2
1Department of Mechanical Engineering, Inha University, Inha-ro 100, Incheon, Republic of Korea.
Abstract:
Among chemical warfare agents (CWAs), mustard gas (HD) is a lethal blister agent that causes prolonged chemical burns and skin blistering, often without immediate symptoms. HD has been used as a chemical weapon due to its potent toxicity, which becomes more pronounced as temperatures rise after its release in colder conditions. As temperature increases, HD also undergoes more active desorption, making its detection increasingly difficult. Therefore, temperature-sensitive detection methods are critical for effectively identifying HD for practical applications in this field. In this study, we investigated the detection of 2-chloroethyl ethyl sulfide (2-CEES), a simulant for HD, using a surface acoustic wave (SAW) sensor coated with a polyphosphonamide-based polymer (PPD-F2). Experiments were conducted across a temperature range of - 20 °C to 50 °C. The results demonstrated that the sensor's frequency shift (∆f) increased as the temperature decreased, with a particularly notable rise in ∆f observed at temperatures below 10 °C.
More Related Videos
04:09Demonstrating the Simplicity and In Situ Temperature Monitoring of the Mechanochemical Synthesis of Metal Chalcogenides Suitable for Thermoelectrics
Published on: August 30, 2024
08:49Manufacturing Simple and Inexpensive Soil Surface Temperature and Gravimetric Water Content Sensors
Published on: December 21, 2019
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...