Related Experiment Video
Updated: Sep 13, 2025

Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
Published on: October 20, 2016
Tracking progression of aortic stenosis with echocardiography
Clay Sherrill1, Jenna Port1, Mohamad Wahoud1
1Department of Medicine, Tufts Medical Center, 800 Washington St, Boston, MA, 02111, USA.
Transthoracic echocardiography (TTE) markers for aortic stenosis (AS) show varied sensitivity. Mean gradient offers the best signal-to-noise ratio for tracking AS progression in non-severe cases.
Area of Science:
- Cardiology
- Medical Imaging
- Echocardiography
Background:
- Transthoracic echocardiography (TTE) is crucial for assessing aortic stenosis (AS) severity and progression.
- Reliable non-invasive imaging markers are needed for clinical trials evaluating medical therapies for AS.
- The signal-to-noise ratio of TTE measures for progressive, non-severe AS is not well-established.
Purpose of the Study:
- To evaluate the signal-to-noise ratio of commonly used TTE-based hemodynamic markers for assessing progressive (non-severe) aortic stenosis.
- To determine the most reliable TTE marker for tracking disease progression in patients with non-severe AS.
Main Methods:
- Retrospective analysis of TTEs from a tertiary referral center.
- Inclusion of two patient cohorts: those with TTEs within 30 days (reproducibility) and those with TTEs ≥1 year apart (progression), without intervention.
- Calculation of limits of agreement (LOA), intraclass correlation (ICC), and Cohen's d-statistic for aortic valve area (AVA), peak velocity, and mean gradient.
Main Results:
- The progression cohort included 35 patients with a median follow-up of 2.2 years.
- Intraclass correlation coefficients (ICC) indicated poor agreement for peak velocity (0.29) and mean gradient (0.06) in the reproducibility cohort.
- Cohen's d-statistic for annualised change showed the highest value for mean gradient (0.55), followed by peak velocity (0.46) and AVA (-0.29).
Conclusions:
- Standard TTE markers exhibit variable sensitivity in detecting AS progression.
- Mean gradient demonstrates the highest signal-to-noise ratio among assessed TTE markers for progressive, non-severe AS.
- Mean gradient may be the most dependable TTE-based assessment for monitoring disease progression in this patient group.
Related Concept Videos
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Mitral Stenosis II: Clinical features and Diagnostic Tests
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Aneurysm II: Clinical Manifestations and Diagnostic Studies