Related Experiment Video
Updated: Sep 13, 2025

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
Published on: August 30, 2013
A Comparative Analysis of Digital Mammography and Digital Breast Tomosynthesis in Japanese Women
Akemi Hara1, Akihiko Ozaki1,2, Masahiro Wada2,3
1Clinical Research Center, Jyoban Hospital of Tokiwa Foundation, Iwaki, JPN.
Abstract:
Introduction Digital breast tomosynthesis (DBT) addresses the limitations of digital mammography (DM). While DM+DBT is gradually replacing DM in the United States and other Western countries, its adoption in Japan has been limited. This study assessed and compared the diagnostic performance of DM and DM+DBT, with a novel focus on breast density, reader experience, and workflow efficiency in Japanese women who underwent examinations during our early experience shortly after the introduction of DBT. Methods A retrospective review of 48 patients (19 with breast cancer and 29 with benign lesions) who underwent both DM and DBT at Jyoban Hospital was conducted. Five readers (two physicians, one medical resident, and two radiologic technologists) assessed the images. Diagnostic accuracy was evaluated using receiver operating characteristic (ROC) curve analysis for breast density and reader experience in both screening and clinical settings. Inter-reader agreement and reading times were assessed, with paired t-tests used to analyze differences in reading times. Results DM+DBT achieved higher inter-reader agreement than DM (Kappa: 0.708, 95% CI: 0.567-0.849 vs. 0.661, 95% CI: 0.511-0.811), though this difference was not statistically significant (p = 0.653). In screening settings, DM+DBT significantly improved the area under the curve (AUC; 0.750, 95% CI: 0.717-0.784 vs. 0.709, 95% CI: 0.675-0.743; p = 0.005); in clinical settings, the increase was not significant (0.878, 95% CI: 0.834-0.921 vs. 0.844, 95% CI: 0.797-0.891; p = 0.153). For dense breasts, AUC improved notably with DBT (screening: 0.766, 95% CI: 0.699-0.833 vs. 0.684, 95% CI: 0.612-0.756; p = 0.007; clinical: 0.936, 95% CI: 0.883-0.990 vs. 0.827, 95% CI: 0.740-0.914; p = 0.023), but no significant differences were observed in non-dense breasts. All readers improved with DBT, except the medical resident. Reading times increased significantly, from 32.5-82.5 seconds (DM) to 71.3-113.8 seconds (DM+DBT) (p = 0.006). Conclusion DM+DBT improves diagnostic accuracy, particularly for dense breasts in Japanese women, but longer reading times and reader experience may limit its widespread adoption.
More Related Videos
15:48Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
08:32Using Computer-based Image Analysis to Improve Quantification of Lung Metastasis in the 4T1 Breast Cancer Model
Published on: October 2, 2020
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET