A Protocol of Manual Tests to Measure Sensation and Pain in Humans
Published on: December 19, 2016
Intra-Rater Reliability of Pressure Pain Threshold with Different Algometers in Healthy Participants
Alexandre Nunes1,2,3, Vanessa Leite1
1Osteopatia, Escola Superior de Saúde Jean Piaget do Algarve, Enxerim, 8300-025 Silves, Portugal.
Background:
Algometry is a validated and reliable measurement tool, but there are still no reliable data for the different algometers used by different raters in the same participant.
Objective:
The aim of this study was to determine the intra-reliability of pressure pain thresholds (PPTs) measured using a digital algometer with and without a digital screen by different raters at the same time in a pain-free population.
Methods:
Participants were healthy adults. PPTs were assessed using two different algometers: a digital algometer with a digital screen for a feedback of the pressure curve rate (SpTech Digital Algometer); and a digital algometer without a screen (Wagner Instruments FDX-25, Greenwich, CT, USA). Four PPT points were used: upper trapezius, lumbar spine, extensor carpi ulnaris, and tibialis anterior. The Copenhagen Psychosocial Questionnaire II was used to assess burnout, stress, sleeping problems, depressive symptoms, somatic stress, and cognitive stress. The intraclass coefficients (ICCs) for intra-rater reliability was calculated using a two-way mixed effects model, single measurement type, and absolute agreement definition.
Results:
A total of 47 healthy participants with a mean age of 30.51 (11.35) years were included. The upper trapezius and extensor carpi ulnaris had the lowest PPT values, and the tibialis anterior had the highest PPT value. Females had the lowest PPT values when compared with males with p < 0.05 in the upper trapezius and extensor carpi ulnaris regions. The intra-rater reliability ranged from good to excellent reliability, with the ICC values of rater 1 being higher when compared with rater 2. The PPT in tibialis anterior had the highest mean ICC scores.
Conclusions:
The intra-rater reliability of PPTs measured by different digital algometers ranged from good to excellent reliability. The rater with more experience demonstrated higher reliability.
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.