Related Experiment Video
Updated: Sep 12, 2025

In Vitro Thrombosis Test for Ventricular Assist Devices
Published on: March 21, 2025
Protocol of the Comparison of Two Different Bicarbonate Replacement Fluids during Continuous Veno-Venous
Paul Köglberger1,2, Fabian Perschinka1, Sebastian J Klein1
1Division of Intensive Care and Emergency Medicine, Department of Internal Medicine, Medical University Innsbruck, Innsbruck, Austria.
Introduction:
Acid-base disturbances are common issues during continuous veno-venous hemofiltration (CVVH). Especially using regional citrate anticoagulation (RCA), recent studies have shown that control in intracorporal pH and HCO3 concentration may be improved when the replacement fluid is changed to a solution with a lower
Methods:
This is a prospective, randomized, controlled, open-label, crossover, phase II, single-center study involving critically ill patients requiring RRT. The two replacement fluids (Phoxilium and Biphozyl) are compared in two groups with 1:1 block randomization and consecutive crossover after 48 h of CVVH. The primary endpoints are the occurrence of at least one pH (>7.45) or
Conclusion:
Given the broad inclusion and restricted exclusion criteria, we expect the results of the BiPhox-Trial to be broadly applicable to patients in need of CVVH with RCA in the intensive care setting. This trial aims to determine whether the use of LBF results in more stable acid-base parameters compared to HBF during CVVH with RCA in critically ill patients and may guide therapeutic decisions in clinical practice.
More Related Videos
Related Concept Videos
Continuous Renal Replacement Therapy
Titration of Polyprotic Base with a Strong Acid
Hemodialysis II: Procedure and Complications
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to...
Bicarbonate-Carbonic Acid Buffer