Observations in incorporating lung ultrasound views into the echo lab: value in decompensated heart failure
Mariam B Camacho1, Samantha R Spierling Bagsic2, Santiago Camacho3
1Department of Medicine, Scripps Mercy Hospital, San Diego, CA, USA. mariam.bonyadi@gmail.com.
Background:
Although lung ultrasound (LUS) can detect specific findings in decompensated congestive heart failure (dCHF), it is largely unavailable to hospitalized patients outside of point-of-care ultrasound practice. Therefore, we sought to determine if 4 lung views added value to echocardiography and whether LUS could be performed expeditiously in an inpatient echo lab.
Methods:
Consecutive inpatient echo studies from a 300-bed community hospital included two posterobasal and two anteroapical lung views and were retrospectively reviewed for: (1) echo parameters including EF < 40%, E/e'>13, pseudonormal E/A ratio, among others, of which the presence of any one parameter defined an abnormal echocardiogram, Echo+, and (2) LUS bilateral findings of 3-or-more B-lines or pleural effusion defined an abnormal lung study, LUS+. Patient charts were reviewed for the clinical diagnosis of dCHF as the reference standard. Diagnostic accuracies were determined for Echo, LUS, and their combination in predicting dCHF by univariate and area under the receiver-operating characteristic (AUC) analyses. The time necessary to perform the LUS was recorded.
Results:
Of n = 129 inpatients, mean (±SD) patient age was 67.0 ± 16.3 years, 57% were male, 32/129 (25%) had dCHF. LUS + was present in 65/129 (50%) and was related to dCHF (p < 0.0001). Despite the high 91% sensitivity of Echo + alone, the addition of LUS findings improved specificity from 49 to 89% and accuracy from 60 to 84%. Lung imaging views required only 95 s ± 42 [range: 30-227] to perform.
Conclusions:
The addition of 4 simple lung views to the standard echocardiogram improves diagnostic accuracy for decompensated CHF without increasing imaging resources. These pilot data support integrating lung ultrasound with standard echocardiography for healthcare delivery in hospital settings.
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Ultrasonography
During an ultrasonography procedure, a handheld device called...