Exploring supervised machine learning models to estimate blood pressure using non-fiducial features of the
Erick Javier Argüello-Prada1, Carlos David Castaño Mosquera2
1Programa de Bioingeniería, Facultad de Ingeniería, Universidad Santiago de Cali, Calle 5 # 62-00 Barrio Pampalinda, Cali, 760032, Valle del Cauca, Colombia. erick.arguello00@usc.edu.co.
Abstract:
Machine learning has proven valuable in developing photoplethysmography (PPG)-based approaches for blood pressure (BP) estimation, with many holding some promise for cuff-less BP assessment. Still, their efficacy relies on accurate and robust fiducial point detection algorithms. The present study explores the usefulness of several non-fiducial features of the PPG signal and its derivatives in estimating BP by combining well-known feature selection methods and machine learning techniques. We collected PPG recordings from 56 participants and computed fifty-seven non-fiducial features, including statistical indexes and energy operators. After implementing three feature selection algorithms (i.e., F-test, mRMR, and ReliefF), the most relevant features were employed to train four learning regression model families. We computed the mean of all absolute errors (MAE), the squared sum and the standard deviation of the errors (MSE and RMSE, respectively), and the coefficient of determination (r2) to evaluate the performance of each model. The abovementioned feature selection methods produced different optimal feature subsets for systolic and diastolic BP values, with the Matern 5/2 and the rational quadratic GPR models providing the best predictions when combined with ReliefF (MAE = 0.44, MSE = 0.61, and RMSE = 0.78 mmHg for SBP; MAE = 0.31, MSE = 0.40, and RMSE = 0.63 mmHg for DBP). Furthermore, each model utilizes only fifteen easy-to-compute features, thus becoming suitable for computationally constrained hardware. We highlight the need for implementing feature selection algorithms exhaustively, as the most relevant PPG-based features for systolic and diastolic BP estimation might not have the same weight.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Measurement of Blood Pressure
Pre-Procedural Guidelines for Assessing Blood Pressure
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.