Development of Enhanced Separation Techniques for Oligonucleotides Utilizing Mixed-Mode Chromatography and
Jakob Haglöf1, Jenny M Nilsson1, Jufang Wu Ludvigsson2
1Department of Medicinal Chemistry, Uppsala Biomedical Centre, Uppsala University, Uppsala, Sweden.
Abstract:
Oligonucleotides are traditionally analyzed using ion-pair reversed-phase liquid chromatography. In this project, we explored an alternative approach utilizing a reversed phase-weak anion exchange mixed-mode column, which combines separation based on both charge and hydrophobicity. Our findings indicate that the mixed-mode column provided stronger retention and superior separation compared to the C18 column, eliminating the need for ion-pairing reagents. Additionally, selectivity can be adjusted using gradient pH and buffer concentration as well as acetonitrile content. However, the use of a phosphate buffer was necessary to ensure adequate retention and separation, despite its incompatibility with MS detection. To address this issue, a 2DLC-UV-qTOF setup with multiple loops was established, where the second-dimension LC, connected to the MS detector, required only an MS-compatible mobile phase. Using a HILIC-type LUNA Omega Sugar column in the second-dimension LC, the MS intensity of the heart-cut from the first dimension was increased 100-fold, allowing for the characterization of the main peak.
More Related Videos
10:41Ion Exchange Chromatography IEX Coupled to Multi-angle Light Scattering MALS for Protein Separation and Characterization
Published on: April 5, 2019
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
High-Performance Liquid Chromatography: Elution Process
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...