Related Experiment Video
Updated: Jul 16, 2026

Echocardiographic Approaches and Protocols for Comprehensive Phenotypic Characterization of Valvular Heart Disease in Mice
Published on: February 14, 2017
Auscultatory and echophonocardiographic characteristics of the normally functioning Medtronic-Hall aortic valve
Abstract:
We recorded auscultatory and echophonocardiographic findings in 30 patients who had a normally functioning Medtronic-Hall (M-H) tilting disc valve prosthesis in the aortic position. The opening and closing sounds were invariably audible. Echophonocardiography showed that a typical opening sound consisted of 2 or 3 sharp clicks which were related to the onset and termination of the disc opening excursion. The closing sound comprised at least 2 separate clicks which coincided with the onset and completion of the valve closure. An early systolic ejection type murmur was heard in 25 patients and a faint early diastolic murmur in 2. The disc motion could be recorded echocardiographically in 27 patients. The opening amplitude of the disc varied from 3 to 11 mm. The intervals from the Q wave and the first heart sound to the onset of valve opening measured 116 +/- 20 ms (mean +/- standard deviation) and 54 +/- 14 ms, respectively. The opening and closing velocities of the disc were also easily measurable but showed a wide patient-to-patient variation. In 5 patients, the examination was repeated after 8 to 12 months. The reproducibility was excellent for the auscultatory findings and fair for the echophonocardiographic time intervals and disc opening amplitude, but poor for the disc velocities. Familiarity with these normal findings should help clinicians to determine whether an aortic M-H valve functions normally or not.
Related Concept Videos
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V) valves at the...
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Cardiovascular System Abnormal Findings II: Auscultation
Abnormal Heart Sounds
Gallops:
Mitral Regurgitation II: Clinical Features and Diagnostic Tests
Mitral Stenosis II: Clinical features and Diagnostic Tests
Aortic Regurgitation II: Clinical Features and Diagnostic Tests

