Related Experiment Video
Updated: Sep 12, 2025

Quantification and Size-profiling of Extracellular Vesicles Using Tunable Resistive Pulse Sensing
Published on: October 19, 2014
Determination of Absolute Injection Volume in Capillary Electrophoresis by the "Capillary-Volume-Plateau Calibration
Quan Duc Le1,2, Ngoc Le1,2, Lewis Nguyen1,2
1Department of Chemistry, York University, 4700 Keele St., Toronto, ON M3J 1P3, Canada.
Abstract:
Accurate knowledge of injection volumes is essential for quantitative capillary electrophoresis (CE), yet volumes predicted by the Hagen-Poiseuille equation become unreliable at low pressures or with short injection times. We present a self-referenced approach, termed the Capillary-Volume-Plateau Calibration (CVPC) method, that uses capillary volume as a reference and requires only a one-point calibration to obtain absolute injection volumes (Vinj) without measuring pressure, time, or viscosity. The working relation, Vinj = VA/(kCtm), depends only on five readily measured quantities: (i) the capillary volume, V = πr2l (r is the inner radius and l is the injection-to-detector length), (ii) the detector constant k (signal per concentration unit), (iii) the analyte concentration C, (iv) the peak area A, and (v) the peak migration time tm. If the detector responds linearly with concentration, the constant k is obtained from a single pressure-driven run: a reference solution of known concentration Cref is introduced just long enough to generate a flat-top plateau, and the average plateau signal ⟨S⟩ gives k = ⟨S⟩/Cref. Error analysis shows that the uncertainty in peak area is the dominant contributor to the overall uncertainty in CVPC-determined Vinj, which remains below 4% under typical CE conditions. A test on a commercial instrument with a built-in Hagen-Poiseuille-based predictor revealed overestimates in Vinj of up to approximately 120%, a bias eliminated by the CVPC method. Because the CVPC procedure relies solely on a detector calibration and fixed geometric dimensions, it is based on first principles and remains valid unless detector settings or buffer composition change, offering a practical and broadly applicable route to accurate volume determination in CE.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
09:22Absolute Quantitation of Inositol Pyrophosphates by Capillary Electrophoresis Electrospray Ionization Mass Spectrometry
Published on: August 13, 2021
Related Concept Videos
Capillary Electrophoresis: Instrumentation
Electrophoresis: Overview
There...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
High-Performance Liquid Chromatography: Elution Process