Related Experiment Video
Updated: Sep 12, 2025

Determination of Aggregate Surface Morphology at the Interfacial Transition Zone ITZ
Published on: December 16, 2019
Multiscale investigation of thermally activated coal gangue aggregate concrete interfacial transition zone evolution
Jie Zhou1, Shengpeng Hao2,3, Yong Chen4
1Lanzhou Coal Mine Design and Research Institute Co., Ltd, Lanzhou, 730000, China.
Abstract:
The large‑scale accumulation of coal gangue poses serious environmental and land‑use challenges, yet its direct use as concrete aggregate has been hindered by low reactivity, high porosity, and weak interfacial bonding. Although prior studies have examined thermal activation of coal gangue, the interplay among calcination temperature, pore‑size evolution, and mesoscale failure mechanisms in a unified multi‑scale framework remains underexplored. This study presents a multi‑scale experimental and numerical investigation of thermally activated coal gangue aggregate concrete, focusing on ITZ evolution and failure mechanisms. Coal gangue was calcined at 500, 600, 700, and 800 °C and substituted for natural coarse aggregate in C30 concrete. Uniaxial compression testing, SEM, XRD, NMR, and PFC3D meso‑scale simulations were employed to elucidate the effects of calcination temperature on 28‑day compressive strength, ITZ microstructure, pore‑size distribution, and crack initiation and propagation. Calcination at 700-800 °C maximized the release of active SiO₂/Al₂O₃, resulting in a denser ITZ, reduced porosity, and a 15.6-22.8% increase in compressive strength over uncalcined concrete. Calibrated meso‑scale models demonstrated that enhanced ITZ bond strength delayed crack onset and altered damage patterns. These findings offer theoretical insight and practical guidance for the sustainable valorization of coal gangue in high‑performance concrete applications.
More Related Videos
10:27A Uniaxial Compression Experiment with CO2-Bearing Coal Using a Visualized and Constant-Volume Gas-Solid Coupling Test System
Published on: June 12, 2019
09:00Visualization of Failure and the Associated Grain-Scale Mechanical Behavior of Granular Soils under Shear using Synchrotron X-Ray Micro-Tomography
Published on: September 29, 2019
Related Concept Videos
Microcracking in Concrete
Transition Zone
Alkali Aggregate Reaction in Concrete
Unsoundness of Aggregate due to Volume Change
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Creep in Concrete