Ipsilateral and contralateral acoustic reflexes in neonates.

P M McMillan, M J Bennett, C D Marchant

    Ear and Hearing
    |November 1, 1985
    PubMed
    Summary

    A 660 Hz probe tone significantly improved the detection of acoustic reflexes in neonates compared to a 220 Hz tone. Neonatal thresholds were similar to adults, but intrameatal sound pressure levels were higher than expected.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    The impact of frailty on functional recovery after cardiac surgery-a case control study.

    Perioperative medicine (London, England)·2025
    Same author

    Utilisation of CO<sub>2</sub> as "Structure Modifier" of Inorganic Solids.

    Chemistry (Weinheim an der Bergstrasse, Germany)·2021
    Same author

    Patient factors that influence cerebral desaturation during transcatheter aortic valve implantation.

    British journal of anaesthesia·2016
    Same author

    The impact of haemodilution and bypass pump flow on cerebral oxygen desaturation during cardiopulmonary bypass--A comparison of two systems of cardiopulmonary bypass.

    Perfusion·2014
    Same author

    Organize and conduct demonstrations.

    Medical teacher·2014
    Same author

    cDNA sequence and differential expression of the gene encoding the glutamine synthetase γ polypeptide ofPhaseolus vulgaris L.

    Plant molecular biology·2013

    Area of Science:

    • Audiology
    • Neonatal Hearing Screening

    Background:

    • Acoustic reflexes are crucial for assessing auditory pathway function.
    • Understanding neonatal acoustic reflexes aids in early detection of hearing impairments.

    Purpose of the Study:

    • To evaluate the efficacy of different probe tones (220 Hz vs. 660 Hz) for detecting acoustic reflexes in neonates.
    • To compare neonatal and adult acoustic reflex thresholds.
    • To assess intrameatal sound pressure levels in neonates.

    Main Methods:

    • Ipsilateral and contralateral acoustic reflexes were measured in neonates.
    • 220 Hz and 660 Hz probe tones were used with various activator frequencies (500, 1000, 2000, 4000 Hz).
    • Activator sound pressure level and intrameatal sound pressure levels were recorded.

    Related Experiment Videos

    Main Results:

    • A 660 Hz probe tone detected reflexes three times more frequently than a 220 Hz probe tone.
    • Maximum detection rates (76%) were achieved with 1000/2000 Hz activators and the 660 Hz probe tone.
    • Neonatal ipsilateral thresholds were comparable to adult thresholds at 500, 1000, and 4000 Hz.
    • Neonatal intrameatal sound pressure levels for ipsilateral activators were significantly higher than manufacturer specifications.

    Conclusions:

    • The 660 Hz probe tone is superior for neonatal acoustic reflex testing.
    • Neonatal hearing appears comparable to adult hearing at specific frequencies.
    • Calibration of sound pressure levels in neonatal testing may require adjustment.