O-cresol Concentration Online Measurement Based On Near Infrared Spectroscopy Via Partial Least Square Regression
Published on: November 8, 2019
Complex-Valued Chemometrics in Spectroscopy: Inverse Least Squares Regression
Thomas G Mayerhöfer1,2, Oleksii Ilchenko3,4, Andrii Kutsyk4
1Leibniz Institute of Photonic Technology (IPHT), Jena, Germany.
Complex-valued inverse least squares (ILS) regression improves mixture analysis by using complex refractive index data. This advanced method significantly reduces errors in concentration calculations for chemical mixtures.
Area of Science:
- Analytical Chemistry
- Spectroscopy
- Chemometrics
Background:
- Classical least squares (CLS) regression requires prior knowledge of mixture components.
- Inverse least squares (ILS) regression overcomes this limitation.
- Complex-valued ILS further enhances ILS by utilizing complex refractive index data.
Purpose of the Study:
- To demonstrate the effectiveness of complex-valued ILS in determining component concentrations without prior knowledge.
- To showcase performance enhancements in thermodynamically ideal mixtures.
- To explore error reduction strategies using complex-valued data.
Main Methods:
- Application of complex-valued inverse least squares (ILS) regression.
- Utilizing the complex refractive index function.
- Employing leave-one-out cross-validation (LVOOCV) scheme.
- Leveraging correlations between errors and imaginary concentration components.
Main Results:
- Achieved over 50% reduction in mean absolute error for benzene-toluene and benzene-cyclohexane mixtures.
- Demonstrated significant error reduction by incorporating complex refractive index data.
- Identified additional error reduction through error-imaginary component correlations.
Conclusions:
- Complex-valued ILS offers superior performance for mixture analysis compared to traditional methods.
- The complex refractive index function, obtainable via infrared spectroscopy and Kramers-Kronig relations, is key to this improvement.
- Complex-valued machine learning holds significant potential for advancing analytical applications.
More Related Videos
07:11ARL Spectral Fitting as an Application to Augment Spectral Data via Franck-Condon Lineshape Analysis and Color Analysis
Published on: August 19, 2021
08:49Author Spotlight: Unveiling the Potential of VSFG Microscopy in Studying Mesoscopically Heterogeneous Self-Assembled Structures
Published on: December 1, 2023
Related Concept Videos
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
According to Hooke's law, the vibrational frequency is directly proportional to...
Residuals and Least-Squares Property
If the observed data point lies above the line, the residual is positive, and the line underestimates the actual data value for y. If the observed data point lies below the line, the residual is negative, and the line overestimates the actual data value for y.
The process of fitting the best-fit...
UV–Vis Spectroscopy of Conjugated Systems
One of the factors influencing λmax is the extent...
Spectroscopy of Carboxylic Acid Derivatives