Home-Based Monitor for Gait and Activity Analysis
Published on: August 8, 2019
From Steps to Mobility Levels: Validating a Consumer-Grade Activity Monitor for Automated Recording of Patient
Jan Stenum1, Eric Stewart1, Daniel L Young1,2
1Department of Physical Medicine and Rehabilitation, The Johns Hopkins University School of Medicine, Baltimore, Maryland, United States.
None:
Patient mobility during hospitalization is essential for high-quality healthcare as mobility is linked to physical function and quality of life. The Johns Hopkins Highest Level of Mobility (JH-HLM) scale is a validated method to assess mobility in hospitalized patients. Although the JH-HLM is widely utilized, it has limitations including ceiling effects, unobserved mobility events going unrecorded, and the staff time needed to observe and document.We explored the feasibility of using a consumer-grade activity monitor (Fitbit) to predict JH-HLM scores and address these limitations.JH-HLM scores and step counts were recorded simultaneously using behavioral mapping and analyzed over 1-hour periods among inpatients. We predicted JH-HLM scores based on step counts by fitting ordinal logistic regressions, according to three categorizations of JH-HLM scores reflecting increasing mobility-granularity.We collected data for 189 patient-hours in a cohort of 20 participants. Step counts increased with higher JH-HLM mobility scores. When predicting JH-HLM scores from step counts, there was a trade-off between accuracy and mobility granularity: overall accuracy was 75% when categorizing patient-hours as immobility (JH-HLM of 1 to 5) or mobility (JH-HLM of 6 to 8); accuracy was 68% when categorizing immobility, shorter walking behavior (JH-HLM of 6 to 7), and longer walking behavior (JH-HLM of 8); accuracy was 61% when categorizing immobility and three progressively higher volumes of walking (JH-HLM of 6, 7 and 8).Step counts from the activity monitor could be used to predict whether a patient was immobile or mobile but may lack the sensitivity to accurately predict specific mobility levels.
More Related Videos
06:49Evaluation of a Smartphone-based Human Activity Recognition System in a Daily Living Environment
Published on: December 11, 2015
11:21Methodology for Establishing a Community-Wide Life Laboratory for Capturing Unobtrusive and Continuous Remote Activity and Health Data
Published on: July 27, 2018
Related Concept Videos
Holter Monitor: 24-Hour Monitoring
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.