Related Experiment Video
Updated: Sep 12, 2025

Using Near-Infrared Spectroscopy Wearable Devices to Identify Central Versus Peripheral Limitations During Exercise
Published on: December 19, 2024
Validity of V̇O2max estimates from the forerunner 245 smartwatch in highly vs. moderately trained endurance athletes
Florian A Engel1, Lukas Masur2, Billy Sperlich3
1Integrative and Experimental Exercise Science and Training, Institute of Sport Science, Julius-Maximilians-Universität Würzburg, Judenbühlweg 11, 97082, Würzburg, Germany. florian.engel@uni-wuerzburg.de.
Purpose:
Assessing the validity of maximum oxygen uptake (V̇O₂max) estimates provided by a commercially available smartwatch (Garmin Forerunner 245, Garmin Ltd., Olathe, USA) compared to laboratory-based respiratory gas analysis in moderately-to-highly trained athletes.
Methods:
Thirty-five endurance athletes (Tier 2-3 athletes, 24 males, 11 females; age: 25.1 ± 3.5 years; V̇O₂max: 60.1 ± 8.2 ml·min⁻1·kg⁻1) completed a treadmill ramp test with respiratory gas analysis to determine criterion V̇O₂max. Additionally, each athlete performed two submaximal 15-min outdoor runs at > 70% of maximum heart rate, during which the smartwatch estimated V̇O₂max. Athletes were stratified into moderately trained (V̇O₂max ≤ 59.8 ml·min⁻1·kg⁻1) and highly trained (V̇O₂max > 59.8 ml·min⁻1·kg⁻1) subgroups.
Results:
Across all athletes, the smartwatch underestimated V̇O₂max [mean differences: - 4.73 ml·min⁻1·kg⁻1 (run 1), -4.05 ml·min⁻1·kg⁻1 (run 2)]. Intraclass correlation coefficients (ICC) indicated moderate agreement between smartwatch and laboratory values (run 1: ICC = 0.71 [95% CI: 0.03-0.90]; run 2: ICC = 0.75 [95% CI: 0.17-0.91]), with mean absolute percentage errors (MAPE) of 7.9% and 7.2%. Subgroup analyses revealed better accuracy of smartwatch estimated V̇O₂max in moderately trained group (MAPE: 4.1-2.8%; ICC: 0.63-0.66 [95% CI: 0.09-0.87]), whereas in highly trained athletes, the smartwatch underestimated V̇O₂max by 6.3 ml·min⁻1·kg⁻1 (MAPE: 10.4-9.4%; ICC: 0.34-0.41 [95% CI: - 0.11-0.75]).
Conclusion:
Smartwatch-derived V̇O₂max estimates are valid in moderately trained athletes but less valid in highly trained individuals. While smartwatches are useful for general monitoring, caution is warranted in their interpretation, particularly in highly trained individuals. Laboratory-based gas analysis remains the preferred method when precision is required.
More Related Videos
09:24A Rapidly Incremented Tethered-Swimming Maximal Protocol for Cardiorespiratory Assessment of Swimmers
Published on: January 28, 2020
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Related Concept Videos
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Exercise and Cardiovascular Response
Light to moderate physical activity initiates a series of interconnected responses in the body. The heart rate modestly increases in anticipation of the workout, followed by widespread vasodilation as oxygen consumption by skeletal muscles increases. This results in decreased peripheral resistance, increased capillary blood flow, and accelerated...
Lung Capacity