Related Experiment Video
Updated: Sep 12, 2025
![Automated Preparation of [68Ga]Ga-3BP-3940 on a Synthesis Module for PET Imaging of the Tumor Microenvironment](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F68356.jpg&w=3840&q=50)
Automated Preparation of [68Ga]Ga-3BP-3940 on a Synthesis Module for PET Imaging of the Tumor Microenvironment
Published on: April 25, 2025
Fibroblast activation Protein-Targeted PET/CT using [18 F]FAP-2286 for the evaluation of lung cancer: A comparative
Yu Ma1, Guanghui Liu1, Bulin Du1
1Department of Nuclear Medicine, The First Hospital of China Medical University, 155 Nanjing St, Shenyang, 110001, Liaoning, China.
Purpose:
FAP-2286, which is a novel cyclic peptide that targets fibroblast activation protein (FAP), demonstrates enhanced plasma stability and improved receptor selectivity compared with small-molecule FAP inhibitors (FAPIs). Although [18 F]FAP-2286 exhibits benefits due to the favorable characteristics of fluorine-18-labeled tracers, its diagnostic performance in lung cancer remains to be fully elucidated. This study aimed to compare the diagnostic efficacy of [18 F]FAP-2286 PET/CT with that of [18 F]FDG PET/CT in lung cancer patients.
Methods:
Thirty patients with suspected lung cancer (18 men and 12 women; median age: 64 years [IQR: 35-81]) underwent both [18 F]FAP-2286 and [18 F]FDG PET/CT for initial staging (n = 27) or the detection of recurrence (n = 3). Diagnostic performance was assessed using histopathology and clinical follow-up as reference standards. The quantitative analysis included the maximum standardized uptake value (SUVmax) and target-to-background ratio (TBR).
Results:
Compared with [18 F]FDG, [18 F]FAP-2286 PET/CT significantly increased the TBR in primary tumors (11.60 ± 6.02 vs. 5.80 ± 3.08; P < 0.001), whereas the SUVmax was not significantly different (15.20 ± 8.25 vs. 13.81 ± 7.73; P = 0.524). Although [18 F]FAP-2286 PET/CT demonstrated a lower detection rate for metastatic lymph nodes (67.46% [85/126] vs. 86.51% [109/126]; P < 0.001), it exhibited a higher true positive rate (95.29% vs. 68.81%; P < 0.001). For distant metastases, [18 F]FAP-2286 PET/CT demonstrated superior detection of bone (98.80% vs. 72.46%) and brain lesions (100% vs. 72.73%).
Conclusion:
Compared with [18 F]FDG, [18 F]FAP-2286 PET/CT demonstrates superior performance for detecting bone metastases and provides more accurate N and M staging. These findings suggest that [18 F]FAP-2286 PET/CT may serve as a valuable alternative for the comprehensive evaluation of lung cancer patients.
![An Automated Radiosynthesis of [68Ga]Ga-FAPI-46 for Routine Clinical Use](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F66708.jpg&w=3840&q=50)
