Related Experiment Video
Updated: Sep 12, 2025

Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
Rotationally Asymmetric Refractive Low Addition Multifocal IOL Implantation in Patients With Previous Corneal Laser
Katerina Nouzovská1,2, Mario Canto-Cerdan1, Ana Belen Plaza-Puche1
1Cornea, Cataract, and Refractive Surgery Unit, Vissum (Miranza Group), Alicante, Spain.
Purpose:
To evaluate the visual and refractive outcomes, retinal optical image quality, and patient satisfaction following implantation of a rotationally asymmetric refractive low addition multifocal intraocular lens (IOL) (Lentis Mplus; Te-leon) during cataract surgery in patients with prior myopic corneal laser refractive correction.
Methods:
This observational, retrospective study included 35 eyes (26 patients) with previous laser corneal myopic refractive surgery that were implanted with the LENTIS Mplus (LS-313 MF15) multifocal IOL during cataract surgery. Refractive and visual outcomes were analyzed at 1, 3, and 6 months of follow-up. At the last visit (range: 7 to 130 months), monocular defocus curve and monocular contrast sensitivity were examined. Total ocular aberrometry was obtained with a pyramidal wavefront sensor (Osiris; CSO) at a 4-mm pupil diameter. Patient satisfaction was evaluated with the Quality of Vision (QoV) questionnaire and Near Activity Visual Questionnaire (NAVQ-10).
Results:
A statistically significant improvement was observed in uncorrected and corrected distance visual acuity postoperatively (0.09 ± 0.12 and 0.03 ± 0.12 logarithm of the minimum angle of resolution [logMAR], respectively). Postoperative uncorrected near visual acuity remained nearly unchanged at good levels of 0.38 ± 0.23 logMAR and corrected near visual acuity was 0.09 ± 0.10 logMAR. The monocular defocus curve demonstrated high levels of visual acuity achieved at far and intermediate distances along with acceptable levels at near vision. The QoV questionnaire showed lower scores for frequency (29.12 ± 19.55), severity (29.26 ± 17.40), and bothersomeness (25.87 ± 17.42).
Conclusions:
This study demonstrated efficacy and safety of a rotationally asymmetric refractive low addition multifocal IOL implanted in eyes with prior myopic corneal ablation. It provided good levels of patient satisfaction and spectacle independence.
More Related Videos
Related Concept Videos
Focusing of Light in the Eye
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...

