Related Experiment Video
Updated: Sep 12, 2025

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Digital phantom versus individualised radiation dosimetry in CT examination protocols for children and adults
Antonios E Papadakis1, Apostolos Karantanas2, John Damilakis3
1Medical Physics Department, University Hospital of Heraklion, Stavrakia, Heraklion, Crete, Greece.
Abstract:
The aim of this study was to compare the organ doses estimated through individual model-based and digital phantom-based Monte Carlo (MC) methods in radiation treatment plan-oriented computed tomography (CT) examination protocols. Six physical anthropomorphic phantoms that simulate the average paediatric individual as a neonate, 1-year-old, 5-year-old or 10-year-old child and the average male or female adult individual were used. Organ dose was assessed using two MC-powered dosimetry tools: an individual model-based tool (ImpactMC, CT Imaging GmbH, Germany) and a digital phantom-based dosimetry tool (NCICT, National Cancer Institute, USA). Normalised to volume CT dose index (CTDIvol) organ dose (nOD) was assessed for primarily exposed radiosensitive organs using head, thorax and abdomen/pelvis CT examination protocols intended for radiation treatment plans.nOD were compared with measurements performed using thermoluminescent detectors (TLDs) and physical anthropomorphic phantoms. The average per cent differences between ImpactMC and TLD measurements across all organs and phantoms were 8%, 20% and 16% for head, thorax and abdomen/pelvis, respectively, whereas the corresponding differences between NCICT and TLD measurements were 64%, 48% and 34%. The differences between estimated and measured normalised organ dose values were higher in paediatric than adult phantoms. Compared with NCICT, organ doses estimated with ImpactMC were in closer agreement with TLD measurements: this is due to the methodology employed by ImpactMC to create phantoms that mimic the anatomical characteristics of the examined patient.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System V: CT
X-ray Imaging