Analysis of 18FDG PET/CT Imaging as a Tool for Studying Mycobacterium tuberculosis Infection and Treatment in Non-human Primates
Published on: September 5, 2017
Prognostic Utility of Quantitative PET Parameters on Baseline and Interim FDG-PET Scans in Hodgkin Lymphoma
Natalia Kovaleva1, Shin Hnin Wai2, Niamh Waters2
1Department of Molecular Imaging and Therapy, Austin Health, Melbourne, Victoria, Australia.
Background:
In classical Hodgkin lymphoma (cHL), interim positron emission tomography (iPET) using Deauville Score (DS) guides therapy. Quantitative PET parameters, including changes in maximum standard uptake value [ΔSUVmax], total metabolic tumor volume [ΔTMTV], total lesion glycolysis [ΔTLG], may enhance the predictive value of iPET.
Methods:
This retrospective study analysed 98 cHL patients from 2008 to 2022, assessing quantitative PET parameters at baseline (PET0), after 2 or 3 chemotherapy cycles (iPET), and associations with survival outcomes.
Results:
Advanced-stage disease was present in 45% of patients. At PET0, no parameters were significantly associated with progression-free survival (PFS). At iPET, the only quantitative parameter independently associated with inferior PFS was ΔSUVmax <72% (HR 5.1, 95% CI 1.7-15.5, P = .004). DS positivity was also independently associated with inferior PFS (HR 2.92, 95% CI 1.07-8.01, P = 037). iPET parameters of ΔTLG <99%, and ΔTMTV <99% achieved univariate but not independent statistical significance.
Conclusion:
Larger prospective studies are needed to validate these findings and evaluate quantitative PET parameters in cHL patient risk stratification.
More Related Videos
06:51Utilizing 18F-FDG PET/CT Imaging and Quantitative Histology to Measure Dynamic Changes in the Glucose Metabolism in Mouse Models of Lung Cancer
Published on: July 21, 2018
10:28Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...