Related Experiment Video
Updated: Sep 11, 2025

Morphological and Functional Assessment of the Right Ventricle Using 3D Echocardiography
Published on: October 28, 2020
Quantitative assessment of hypertrophic obstructive cardiomyopathy with intraoperative three-dimensional epicardial
Mireia Pozo Albiol1, Azad Mashari2, Ricard Navarro-Ripoll1
1Department of Anesthesia, Hospital Clinic Barcelona, University of Barcelona, Barcelona, Spain.
Insights
Real-time 3D epicardial echocardiography (EE) is a viable alternative to transesophageal echocardiography (TEE) for assessing hypertrophic obstructive cardiomyopathy (HOCM) during surgery. Both 3D EE and 3D TEE provide comparable measurements for surgical planning.
Area of Science:
- Cardiology
- Medical Imaging
- Surgical Echocardiography
Background:
- Hypertrophic obstructive cardiomyopathy (HOCM) requires precise intraoperative assessment of septal hypertrophy, mitral valve motion, and outflow tract dimensions for effective septal myectomy.
- Transesophageal echocardiography (TEE) is standard but may be contraindicated or suboptimal in some HOCM patients.
- Real-time 3D epicardial echocardiography (EE) offers direct intraoperative visualization without esophageal instrumentation.
Purpose of the Study:
- To compare the utility of 3D EE versus 3D TEE for quantitative assessment of key parameters in HOCM patients undergoing myectomy.
- To determine if 3D EE and 3D TEE measurements are interchangeable for surgical planning.
- To compare 2D and 3D measurements obtained by both EE and TEE.
Main Methods:
- Retrospective review of perioperative data from 59 HOCM patients.
- Acquisition and analysis of 2D and 3D intraoperative EE and TEE studies.
- Application of Altman-Bland analysis to assess measurement interchangeability and Bland-Altman/intraclass correlation for variability.
Main Results:
- 3D EE data analysis was feasible in 79.7% of patients.
- No significant differences were observed between 3D EE and 3D TEE measurements for septal LVWT, SAM distance, or LVOT area (P > 0.22 for all).
- Similarly, 2D measurements by both modalities showed no significant differences.
Conclusions:
- Intraoperative 3D EE is a reliable alternative to TEE for guiding myectomy in HOCM patients, especially when TEE is not feasible.
- EE provides equal potential utility in HOCM surgical guidance, potentially improving surgical outcomes.
- EE serves as a valuable imaging option for HOCM myectomy when TEE is contraindicated.
Background:
Hypertrophic obstructive cardiomyopathy (HOCM), a subset of hypertrophic cardiomyopathy (HCM), is characterized by dynamic left ventricular outflow tract (LVOT) obstruction, often caused by systolic anterior motion (SAM) of the mitral valve and septal hypertrophy. Accurate intraoperative assessment of septal morphology, SAM distance, and LVOT area (LVOTa) is critical for surgical planning during septal myectomy. While transesophageal echocardiography (TEE), particularly with three-dimensional (3D) imaging, is the standard modality for evaluating these parameters, it may be contraindicated or suboptimal in select cases. Real-time 3D epicardial echocardiography (EE) offers an alternative imaging approach that allows direct visualization of the heart intraoperatively without esophageal instrumentation. This study investigates the utility of 3D EE compared to 3D TEE for quantitative assessment of septal left ventricular wall thickness (LVWT), SAM distance, and LVOTa in HOCM patients undergoing myectomy. The primary aim is to assess whether 3D EE and TEE measurements correlate and can be used interchangeably. A secondary aim is to compare 2D and 3D measurements by both modalities.
Methods:
Perioperative data of 59 patients with HOCM were obtained by retrospective review in a tertiary care setting. 2D and 3D intraoperative transesophageal and EE studies were assessed performing multiple measurements relevant for myectomy. Demographic and clinical data were summarized with descriptive statistics, while the Altman-Bland method assessed the interchangeability of three-dimensional transesophageal and EE measurements. Inter- and intraobserver variabilities were evaluated using the Bland-Altman method and intraclass correlation coefficient.
Results:
Off-line analysis of 3D data sets with Qlab Phillips was feasible in 79.7% of the patients. No significant differences were found between epicardial and transesophageal echocardiographic intraoperative measurements by 2D: septal LVWT (P=0.59), SAM distance (P=0.40) or LVOTa (P=0.22), or by 3D: septal LVWT (P=0.42), SAM distance (P=0.23) or LVOTa (P=0.38).
Conclusions:
Intraoperative EE demonstrates equal potential utility in guiding HOCM patients when TEE is not an option or is contraindicated. These findings underscore the clinical significance of EE as a reliable alternative for image guidance during myectomy in HOCM patients, contributing to improved surgical outcomes.
Related Concept Videos
Cardiomyopathy III: Hypertrophic Cardiomyopathy
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...

