Near-Infrared Temperature Measurement Technique for Water Surrounding an Induction-heated Small Magnetic Sphere
Published on: April 30, 2018
Evaluating the accuracy of the variable flip angle technique for temperature measurement near metallic implants
1Department of Radiological Science, Daewon University College, Jecheon, Republic of Korea.
None:
This study assessed the accuracy of a T1-based temperature measurement technique for metal-inserted materials using 3T magnetic resonance imaging (MRI). A variable flip angle (VFA) sequence with dual echoes was used to obtain images of a phantom and an ex vivo experiment. T1 values were calculated when the metal-inserted materials were subjected to heating and were acquired in the proximity of the metal implant of the phantom and ex vivo tissue. The values were converted into temperature measurements using a fiber-optic thermal sensor (FOS) that was placed within the metal substances. Additionally, proton resonance frequency shift (PRFS) was calculated from phase images acquired with the dual echoes, which allow for a comparison of temperature fidelity between the VFA and PRFS techniques. In the phantom experiment, the root mean square temperature error based on T1 values was approximately 0.12 ℃, which was comparable to that obtained from the FOS. In contrast, the PRFS demonstrated a substantial temperature measurement error of approximately 11.21 ℃, as determined by the root mean square calculation. A similar pattern was observed in the ex vivo experiment, where the T1-based temperature measurement error was minimal at approximately 0.30 ℃, while the PRFS-based temperature measurement error was considerably higher at around 5.44 ℃. These findings indicate that the VFA technique enables precise monitoring of temperature alterations in metal-inserted materials, engendering its incorporation into clinical MRI sequences for temperature assessment during magnetic resonance radiofrequency (RF) exposure.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...