Background:
Low-dose computed tomography (LDCT) has become clinically essential for reducing radiation risks, but image noise remains a major challenge. Although deep learning methods have shown promise in denoising, they often fail to preserve fine structures while suppressing noise, particularly in orthopedic imaging where subtle bone textures are diagnostically critical. This study aimed to develop a wavelet-domain frequency-mixing transformer (FMT) network that simultaneously addresses noise suppression and structural preservation in orthopedic LDCT images, overcoming the limitations of current spatial-domain methods.
Methods:
We developed a novel unfolding network integrating (I) multiscale wavelet decomposition for frequency band-specific processing; (II) FMT blocks for cross-band feature interaction; and (III) physics-based noise modeling for realistic denoising. The model was trained and validated with clinical orthopedic scans from medical centers, with quantitative evaluation according to peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM).
Results:
Our method achieved superior performance compared to six state-of-the-art approaches, with a mean PSNR of 42.3 dB (improvement of 3.7 dB over baseline) and an SSIM of 0.961 on the test data. Clinical evaluation by three radiologists confirmed the significantly better preservation of trabecular bone patterns (P<0.01).
Conclusions:
The proposed network establishes a new paradigm for LDCT denoising by explicitly modeling frequency-domain characteristics, demonstrating particular value for orthopedic applications requiring fine structural fidelity. This approach may enable further dose reduction in musculoskeletal imaging without compromising diagnostic quality.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Continuous -time Fourier Transform
Imaging Studies III: Computed Tomography
Deconvolution
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...
Discrete Fourier Transform
Discrete-time Fourier transform
One of the notable...