Related Experiment Video
Updated: Sep 11, 2025

Fully Endoscopic Mitral Valve Repair with Percutaneous Cannulation of Groin Vessels
Published on: May 26, 2023
Comparison of safety and efficacy in venous access closure using a double purse string suture technique vs. Z-suture
Anas Alnaimi1, Sebastian Frederik Mause1, Nawar Alachkar1
1Department of Internal Medicine I, Cardiology, University Hospital Aachen, RWTH Aachen University, Aachen, Germany.
Background:
Percutaneous mitral valve repair using the MitraClip System is a well-established therapeutic option for patients with symptomatic mitral regurgitation. This procedure is usually performed via venous femoral access using a 24-French guiding catheter. Since vascular complications and bleeding remain a relevant limitation, we now compared access closure using subcutaneous absorbable double purse string suture (DPSS) and Z-suture technique following MitraClip procedure.
Methods:
249 patients (mean age 76 ± 8 years) who underwent MitraClip procedure at our institution were included. Venous closure was performed using Z-suture technique in 140 patients and DPSS technique in 109 patients. Vascular complications and bleeding events were assessed according to the Mitral Valve Academic Research Consortium (MVARC) criteria.
Results:
MVARC minor and major vascular complications were comparable after closure with Z-suture and DPSS-technique (4.3% vs. 0.9%, p = 0.11 and 1.4% vs. 0.9%, p = 0.71, respectively). However, development of AV-fistula and requirement of access related surgical intervention was more often observed in the Z-suture group (5% vs. 0%, p = 0.018 and 3.5% vs. 0%, p = 0.045). MVARC minor and major, non-life-threatening bleeding did not differ between the two groups (10.7% vs. 12.9%, p = 0.61 and 0.7% vs. 0.0%, p = 0.38). Similarly, overall transfusion rates and access related blood transfusion rates were comparable (11.4% vs. 15.5%, p = 0.34 and 4.3% vs. 2.7%, p = 0.52).
Conclusion:
Large caliber venous access closure with DPSS technique was feasible, safe, and effective to achieve haemostasis after MitraClip procedure. Compared with Z-suture, use of DPSS closure was associated with a lower rate of required access related surgical intervention and postinterventional AV-fistula.