Abstract:
The development of sensitive and selective probes for cobalt ion (Co2+) detection is critical, given the increasing environmental burden of heavy metal contamination from industrial discharge and its consequences on lifeforms. To this end, we present polyethylenimine-passivated carbon dots (PEI-MCDs), synthesized via a rapid microwave-assisted pyrolysis of Moringa oleifera leaves, as efficient fluorescent nanoprobes for Co2+ detection. Comprehensive spectroscopic and microscopic analyses confirmed that the PEI-MCDs are water-soluble and exhibit excitation-dependent emission. The nanoprobes exhibited a wide linear detection range (20-180 μM) and a low detection limit of 1.1 μM for Co2+ detection, with high accuracy in real water samples. Further investigation of the selective affinity of PEI-MCDs to Co2+ ions with isothermal titration calorimetry (ITC) revealed van der Waals force-driven strong and specific exothermic interactions at the interface. Complementary time-resolved fluorescence studies indicated that Förster resonance energy transfer (FRET) contributes to the observed fluorescence quenching upon Co2+ binding, offering further insight into the energy transfer dynamics at the nanoprobe interface. Together, these findings offer a comprehensive mechanistic understanding of the Co2+-nanoprobe interaction, establishing PEI-MCDs as a promising sustainable platform for reliable, real-time fluorometric detection of cobalt ions in complex water bodies.
More Related Videos
08:18Microscopic Visualization of Porous Nanographenes Synthesized through a Combination of Solution and On-Surface Chemistry
Published on: March 4, 2021
11:38In situ FTIR Spectroscopy as a Tool for Investigation of Gas/Solid Interaction: Water-Enhanced CO2 Adsorption in UiO-66 Metal-Organic Framework
Published on: February 1, 2020
Related Concept Videos
Complexometric Titration: Overview
Controlled-Current Coulometry: Coulometric Titration
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...
Controlled-Current Coulometry: Overview
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Complexometric Titration: Ligands