Enhanced accuracy in gravity-based intravenous infusion using pulse oximeter drop counting and measured single-drop
Daeseok Oh1, Myoung Jin Ko1, Jae Hwan Kim1
1Department of Anesthesiology and Pain Medicine, Inje University Haeundae Paik Hospital, Busan, Korea.
Background:
Intravenous (IV) fluid therapy is essential and widely used; however, it is associated with high error rates, largely due to human factors, necessitating constant and careful monitoring by medical staff. Gravity-based systems are prone to errors, whereas electronic pumps, though more accurate, are limited by size, cost, and complexity. In this study, the impact of single-drop weight measurement and real-time light source monitoring on the accuracy of gravity-based infusion systems was evaluated.
Methods:
Gravity-based IV sets with IV infusion flow regulators (IIFRs) from three manufacturers were tested using 1,000 ml of 0.9% saline. The drops per min and the drop weight were recorded using a pulse oximeter, which served as a light source. The flow rates from the pulse oximeter group (PO) were compared with those from the manufacturer's drop volume (C) and the IIFR groups. The mean absolute percentage error (MAPE) of predicted versus actual volumes was analyzed along with correlations between the residual volume and drop rate.
Results:
The PO group values were statistically closer to those of the actual measurements than the C and IIFR groups values (P < 0.05), demonstrating higher accuracy and lower MAPE, except at 300 ml/h when than those of the C group, independent of residual volume. The residual volume strongly correlated with the drop rate (r > 0.9).
Conclusions:
Real-time drop measurements using light sources combined with single-drop weight assessment improve the accuracy of these systems. Integrating pulse oximeters into IV sets may enhance clinical precision and reduce provider workload.
More Related Videos
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Measurement of Blood Pressure