Related Experiment Video
Updated: Sep 11, 2025

Pedicle Screw Placement Using an Augmented Reality Head-Mounted Display in a Porcine Model
Published on: May 24, 2024
Development and validation of machine learning models to predict vertebral artery injury by C2 pedicle screws
Bo Ye1,2, Yang Sun1, Guolin Chen3
1Department of Spine Surgery, Honghui Hospital, Xi'an Jiaotong University, Shaanxi, China.
Purpose:
Cervical 2 pedicle screw (C2PS) fixation is widely used in posterior cervical surgery but carries risks of vertebral artery injury (VAI), a rare yet severe complication. This study aimed to identify risk factors for VAI during C2PS placement and develop a machine learning (ML)-based predictive model to enhance preoperative risk assessment.
Methods:
Clinical and radiological data from 280 patients undergoing head and neck CT angiography were retrospectively analyzed. Three-dimensional reconstructed images simulated C2PS placement, classifying patients into injury (n = 98) and non-injury (n = 182) groups. Fifteen variables, including characteristic of patients and anatomic variables were evaluated. Eight ML algorithms were trained (70% training cohort) and validated (30% validation cohort). Model performance was assessed using AUC, sensitivity, specificity, and SHAP (SHapley Additive exPlanations) for interpretability.
Results:
Six key risk factors were identified: pedicle diameter, high-riding vertebral artery (HRVA), intra-axial vertebral artery (IAVA), vertebral artery diameter (VAD), distance between the transverse foramen and the posterior end of the vertebral body (TFPEVB) and distance between the vertebral artery and the vertebral body (VAVB). The neural network model (NNet) demonstrated optimal predictive performance, achieving AUCs of 0.929 (training) and 0.936 (validation). SHAP analysis confirmed these variables as primary contributors to VAI risk.
Conclusion:
This study established an ML-driven predictive model for VAI during C2PS placement, highlighting six critical anatomical and radiological risk factors. Integrating this model into clinical workflows may optimize preoperative planning, reduce complications, and improve surgical outcomes. External validation in multicenter cohorts is warranted to enhance generalizability.
More Related Videos
09:07An Anesthesia, Surgery, and Harvest Method for the Evaluation of Transpedicular Screws Using an In Vivo Porcine Lumbar Spine Model
Published on: May 31, 2017
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024