Related Experiment Video
Updated: Sep 11, 2025

Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping
Published on: November 7, 2016
Data correction of temperature and water vapor measurements using the combined lateral scanning Raman scattering
Abstract:
A combined lateral scanning Raman scattering lidar (LSRSL) and backward Raman scattering lidar (BWRSL) is built in Xi'an, which can achieve accurate measurements of atmospheric temperature and water vapor from the ground to the concerned height. In this paper, we report a method to correct the atmospheric transmittance in the return path, which is due to the wavelength difference between the high- and low-quantum-number transitions of PRRSS for temperature measurements and between the VRSS of N2 and H2O for water vapor measurements. The correction function of atmospheric transmittance is optimized by considering the effect of aerosols from nearby industry and local urban traffic on atmospheric transmittance. With the advantages of the LSRSL system in the atmospheric detection without overlap effect, the atmospheric transmittance in the slant path of the LSRSL system is calculated from the real-time measured aerosol extinction from the lateral vibrational Raman scattering signal of N2, while the atmospheric transmittance in the return path of the BWRSL system is calculated from the glued aerosol extinction from both LSRSL system and BWRSL system. The retrieval results after data correction show that the combined lidar system can realize the detection of atmospheric temperature and water vapor from the ground to the height of 4.30 km under complex weather conditions, with a temperature deviation of less than 1.05 K and the water vapor deviation less than 0.61 g/kg compared with radiosonde data.
More Related Videos
08:52Near-Infrared Temperature Measurement Technique for Water Surrounding an Induction-heated Small Magnetic Sphere
Published on: April 30, 2018
09:46Direct Comparison of Hyperspectral Stimulated Raman Scattering and Coherent Anti-Stokes Raman Scattering Microscopy for Chemical Imaging
Published on: April 28, 2022
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Distance Corrections
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...