Choosing the Correct Internal Reference Redox Species for Overcoming Reference Electrode Drift in Voltammetric pH
Nafiz B Biswas1, Tania Read1, Katherine J Levey1,2
1Department of Chemistry, University of Warwick, Coventry CV4 7AL, United Kingdom.
None:
Reference electrode (RE) drift is a common problem when electrodes are used for pH determination, especially over extended periods of time or in complex media. For voltammetric pH measurements, one method to mitigate against RE drift is to add a second pH insensitive redox species (the internal reference, IREF) and measure the difference in peak potential, E diff, between the signal associated with the pH sensitive species, E pH, and IREF, E IREF. This work strategically explores how to choose the correct IREF species. For these studies, a quinone-functionalized boron doped diamond (BDD-Q) electrode is employed as the pH sensing electrode over the pH range of 4-9. To avoid errors in reporting of the real E pH and E IREF values, there must be a minimum separation between the two peaks. Moreover, the distance on the potential axis between a peak and that of the current response pertaining to water electrolysis must also be considered. For the BDD-Q pH electrode, an operable potential window for IREF is established and the IREF redox species, hexachloroiridate (IrCl6 2-/3-), is determined to be most appropriate, showing an ∼0.08 pH error over the pH range of 4-9 and reducing to ∼0.02 pH error over the pH range of 6-8. The use of E diff is further assessed via the voltammetric measurement of dissolved carbon dioxide (CO2) in a Stow-Severinghaus arrangement over the partial pressure range of 30.4-152.0 mmHg. The R 2 linearity of the calibration line (=0.998) is shown to be equivalent and in agreement with theory when plotting either E diff or E pH versus CO2 partial pressure. This data bodes well for the use of E diff as a measurement signal in Stow-Severinghaus dissolved CO2 transcutaneous sensors, where continuous measurement of pH over several days is required.
Related Concept Videos
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Ladder Diagrams: Redox Equilibria
Consider the Fe3+/Fe2+ half-reaction, which has a standard-state potential of +0.771 V. At potentials more positive than +0.771 V, Fe3+ predominates, whereas Fe2+...
Voltammetry: Factors Affecting Measurements
Concentration Cells
Consider the following voltaic cell: