Related Experiment Video
Updated: Jun 20, 2026

Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
Evaluating the effect of extra-cerebral off-target binding in [F-18]MK6240 PET scans in early-stage Alzheimer's
Andrew McVea1,2, Alexandra DiFilippo1,2, Max J McLachlan1,2
1Department of Medical Physics, University of Wisconsin - Madison School of Public Health, Madison, WI, United States.
Abstract:
[F-18]MK6240 is a Positron Emission Tomography (PET) radioligand with favorable imaging characteristics for measuring tau aggregation in Alzheimer's disease (AD). In this study, we investigated the impact of extra-cerebral off-target binding (ECB) in the meninges and sinus present in [F-18]MK6240 PET scans on quantifying tau burden in preclinical AD. Based on large cohort data from 433 [F-18]MK6240 scans acquired at the University of Wisconsin-Madison, simulations were conducted to examine the range of effects of ECB by varying the ECB profile and input radiotracer concentration curves on areas of early tau accumulation in AD. The range and patterning of ECB in the imaging cohort had high variability between participants; however, 35% revealed moderate to high meningeal signal that could influence quantification. Partial volume effects, which can lead to measured PET signal from neighboring regions influencing signal in adjacent areas of interest, were examined in the simulated images. The simulations demonstrate that signal from the sinus increases the neighboring entorhinal cortex region (ERC) signal and activity detected from the meninges can similarly influence the inferior cerebellar grey matter reference region. ECB effects from the sinus were the most prevalent in our cohort, and simulations with the average ECB profile had ERC uptake (SUV) 23% higher than simulations with no ECB. Spill-in effects from the sinus, which increases the medial and ventral temporal cortex standardized uptake value ratio (SUVR), and spill-in from the meninges into the cerebellar reference region, which leads to a reduction in global SUVR, act in opposite directions, complicating the interpretation of the derived SUVR of [F-18]MK6240 images. These simulation results quantify the effects of ECB in [F-18]MK6240 scans and introduce correction factors to minimize bias of the SUVR measure.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Brain Imaging
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans), magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), and Transcranial Magnetic Stimulation (TMS).

