Related Experiment Video
Updated: Sep 11, 2025

Diffusion Imaging in the Rat Cervical Spinal Cord
Published on: April 7, 2015
Robust frequency-dependent diffusional kurtosis computation using an efficient direction scheme, axisymmetric
Jake Hamilton1,2, Kathy Xu3,4, Nicole Geremia3,4
1Centre for Functional and Metabolic Mapping (CFMM), Robarts Research Institute, University of Western Ontario, London, Canada.
Abstract:
Frequency-dependent diffusion MRI (dMRI) using oscillating gradient encoding and diffusional kurtosis imaging (DKI) techniques have been shown to provide additional insight into tissue microstructure compared to conventional dMRI. However, a technical challenge when combining these techniques is that the generation of the large b-values (≥2000 s/mm2) required for DKI is difficult when using oscillating gradient diffusion encoding. While efficient encoding schemes can enable larger b-values by maximizing multiple gradient channels simultaneously, they do not have sufficient directions to enable the estimation of directional kurtosis parameters. Accordingly, we investigate a DKI fitting algorithm that combines axisymmetric DKI fitting, a prior that enforces the same axis of symmetry for all oscillating gradient frequencies, and spatial regularization, which together enable robust DKI fitting for a 10-direction scheme that offers double the b-value compared to traditional encoding schemes. Using data from mice (oscillating frequencies of 0, 60, and 120 Hz) and humans (0 Hz only), we first show that axisymmetric DKI fitting provides comparable or even slightly improved image quality as compared to kurtosis tensor fitting, and improved DKI map quality when using an efficient encoding scheme with averaging as compared to a traditional scheme with more encoding directions. We also demonstrate that enforcing consistent axes of symmetries across frequencies improves fitting quality, and spatial regularization during fitting preserves spatial features better than using Gaussian filtering prior to fitting, which is an oft-reported pre-processing step for DKI. Thus, the use of an efficient 10-direction scheme combined with the proposed DKI fitting algorithm provides robust maps of frequency-dependent directional kurtosis which may offer increased sensitivity to cytoarchitectural changes that occur at various cellular spatial scales over the course of healthy aging, and due to pathological alterations.
More Related Videos
11:43Easy Measurement of Diffusion Coefficients of EGFP-tagged Plasma Membrane Proteins Using k-Space Image Correlation Spectroscopy
Published on: May 10, 2014
12:15Image Processing Protocol for the Analysis of the Diffusion and Cluster Size of Membrane Receptors by Fluorescence Microscopy
Published on: April 9, 2019
Related Concept Videos
One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation
On...
Maxwell-Boltzmann Distribution: Problem Solving
This distribution function f(v) is defined by saying that the expected number N (v1,v2) of particles with speeds between v1 and v2 is given by
Linear Approximation in Frequency Domain
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear....
Differential Form of Maxwell's Equations
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Curvilinear Motion: Rectangular Components
As the car advances, its position evolves over time. Quantifying the car's velocity involves computing the...