Refractory hypoxaemia in the presence of two common conditions: a case report
José Gregorio Soto Rojas1, Elvira Carrión Ríos1,2, Isabel Maria Jorquera Lozano3,4
1Department of Cardiology, Hospital Universitario Torrecárdenas, Calle Hermandad de Donantes de Sangre, Almería 04009, Spain.
Background:
A 72-year-old woman with a history of bicameral pacemaker implantation 12 years earlier due to high-degree atrioventricular block presented with progressively worsening exertional dyspnoea, which recently became evident even with minimal exertion.
Case Summary:
When the patient consulted, marked hypoxaemia was observed, leading to the exclusion of pulmonary aetiology using computed tomography (CT) angiography. Subsequently, an echocardiogram revealed significant tricuspid regurgitation caused by interference with the pacemaker lead. A bubble study demonstrated a right-to-left shunt in the context of a patent foramen ovale. Given the patient's age, the initial hypothesis was that the shunt direction resulted from a condition causing severe pulmonary hypertension, resembling Eisenmenger syndrome. However, right heart catheterization ruled out significant pulmonary hypertension. Since the presence of a patent foramen ovale had been documented, we also tested positional changes without observing any improvement in the degree of hypoxaemia, thereby ruling out platypnoea-orthodeoxia syndrome.
Discussion:
It was proposed that the direction of the jet and the increase in systolic pressure in the right atrium could explain the type of shunt in the absence of pulmonary hypertension. This was drawing from the nature of pacemaker-mediated tricuspid regurgitation and its rapid progression and eccentricity of the jet. Based on this hypothesis, a percutaneous closure of the foramen was performed, resulting in an almost immediate resolution of the hypoxaemia, as observed in the cath lab.
Related Concept Videos
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Hypoxia
Types of Hypoxia
There are four primary types of hypoxia, each resulting from a different cause:
1. Anemic hypoxia: This type occurs due to insufficient oxygen delivery caused by a lack of red blood cells (RBCs) or RBCs with abnormal or...
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-III
Acute Respiratory Failure-IV