Integrated [18F]FAPI-42 PET/MR improves diagnostic accuracy in breast cancer: comparison with simultaneously acquired

Peng Hou1,2, Jie Lv2, Weige Tan3

  • 1Department of Radiology, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, 106 Zhongshan 2nd Road, Guangzhou, 510080, China.

Abstract

Insights

Fluorine-18-labeled fibroblast activation protein inhibitor 42 (¹⁸F]FAPI-42) PET/MR significantly enhances breast cancer diagnosis by reducing false positives and improving lymph node metastasis detection compared to standard breast MRI. This advanced imaging offers more accurate staging, particularly for challenging lesions.

Area of Science:

  • Oncology
  • Radiology
  • Nuclear Medicine
  • Medical Imaging

Background:

  • Accurate diagnosis and staging of breast cancer are crucial for effective treatment planning.
  • Limitations exist in current breast MRI diagnostic performance, particularly in differentiating benign from malignant lesions and assessing axillary lymph node involvement.
  • Fibroblast activation protein (FAPI) targeted PET imaging shows promise for cancer detection due to FAP's overexpression in tumor-associated fibroblasts.

Purpose of the Study:

  • To evaluate the diagnostic efficacy of fluorine-18-labeled fibroblast activation protein inhibitor 42 ([¹⁸F]FAPI-42) PET/MR compared to standard breast MRI.
  • To assess the ability of [¹⁸F]FAPI-42 PET/MR in identifying primary breast lesions and detecting axillary lymph node metastases.
  • To determine if integrated [¹⁸F]FAPI-42 PET/MR offers improved diagnostic accuracy, specificity, and sensitivity over breast MRI alone.

Main Methods:

  • Prospective study of 64 women with BI-RADS 4 or 5 breast lesions.
  • All participants underwent contrast-enhanced [¹⁸F]FAPI PET/MRI scans.
  • Diagnostic performance was assessed using receiver operating characteristic (ROC) analysis and net reclassification improvement (NRI), with histology and follow-up as the gold standard.

Main Results:

  • Integrated [¹⁸F]FAPI-42 PET/MR demonstrated superior specificity (96%) compared to breast MRI (68%) for primary breast lesions, significantly reducing false positives.
  • For axillary lymph node evaluation, [¹⁸F]FAPI-42 PET/MR showed improved sensitivity (95%) versus breast MRI (62%).
  • [¹⁸F]FAPI-42 PET/MR significantly improved diagnostic accuracy for BI-RADS 4 lesions and enhanced specificity for small lesions (<10 mm).

Conclusions:

  • [¹⁸F]FAPI-42 PET/MR significantly enhances diagnostic accuracy in breast cancer detection and staging compared to conventional breast MRI.
  • This modality excels in reducing false-positive findings and improving the detection of axillary lymph node metastases.
  • [¹⁸F]FAPI-42 PET/MR shows considerable potential for refining breast cancer diagnostics, especially for BI-RADS 4 lesions and small tumors.