Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Design Example: Measuring Distance Between Two Points with Obstructions01:10

Design Example: Measuring Distance Between Two Points with Obstructions

119
When measuring distances in areas with physical obstructions, such as a lake in a field, surveyors must employ techniques to calculate accurate lengths without direct line measurements. One effective method is the offset technique, which allows for precise distance estimation over inaccessible stretches.In this scenario, a surveyor must measure a side of an area that crosses a lake. Since the measuring tape cannot span the lake, the surveyor begins by establishing a baseline that aligns with...
119
Plastic Deformations of Members with a Single Plane of Symmetry01:21

Plastic Deformations of Members with a Single Plane of Symmetry

124
When a structural member undergoes plastic deformation due to bending, it is crucial to understand the position of the neutral axis and the stress distribution. This member, characterized by a single plane of symmetry, exhibits a uniform stress distribution, with negative stress above the neutral axis and positive stress below. Notably, the neutral axis does not align with the centroid of the cross-section. This misalignment is typical in cases where the cross-section is not rectangular or...
124
Distance Corrections01:15

Distance Corrections

81
To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
81

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

NRGN inhibits CD8⁺ T cell effector function by downregulating MHC-I expression through the FMR1-IRF8 axis in hepatocellular carcinoma.

Journal of experimental & clinical cancer research : CR·2026
Same author

Homogenizing Sn-Pb Distribution Through A-Site MA Cations for Efficient All-Perovskite Tandem Solar Cells.

Advanced materials (Deerfield Beach, Fla.)·2026
Same author

Trimodal, uncertainty-guided whole-slide framework for genome-scale spatial expression and image-only virtual perturbation in cancer cohorts.

Genome medicine·2026
Same author

FGO-SLAM++: Real-time Geometry-Aware Gaussian SLAM with Continuous Opacity Field.

IEEE transactions on visualization and computer graphics·2026
Same author

ROS-GS: Relightable Outdoor Scenes With Gaussian Splatting.

IEEE transactions on visualization and computer graphics·2026
Same author

Associations of Solid Fuel Use and Circadian Rhythm Syndrome With Physical Function and Muscle Strength in Middle-Aged and Older Adults: Nationwide Cohort Study in China.

JMIR aging·2026

Related Experiment Video

Updated: Sep 11, 2025

Robotized Testing of Camera Positions to Determine Ideal Configuration for Stereo 3D Visualization of Open-Heart Surgery
05:12

Robotized Testing of Camera Positions to Determine Ideal Configuration for Stereo 3D Visualization of Open-Heart Surgery

Published on: August 12, 2021

2.1K

SPARE: Symmetrized Point-to-Plane Distance for Robust Non-Rigid 3D Registration.

Yuxin Yao, Bailin Deng, Junhui Hou

    IEEE Transactions on Pattern Analysis and Machine Intelligence
    |August 13, 2025
    PubMed
    Summary

    This study introduces SPARE, a new non-rigid registration method using a symmetrized point-to-plane distance for improved accuracy and efficiency. SPARE enhances geometric approximation, outperforming existing techniques in medical image analysis.

    More Related Videos

    Author Spotlight: An Efficient and Robust Software for Automated Fusion of Multiple Preclinical Imaging Modalities
    07:13

    Author Spotlight: An Efficient and Robust Software for Automated Fusion of Multiple Preclinical Imaging Modalities

    Published on: October 27, 2023

    1.3K
    Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
    02:09

    Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function

    Published on: April 12, 2024

    676

    Related Experiment Videos

    Last Updated: Sep 11, 2025

    Robotized Testing of Camera Positions to Determine Ideal Configuration for Stereo 3D Visualization of Open-Heart Surgery
    05:12

    Robotized Testing of Camera Positions to Determine Ideal Configuration for Stereo 3D Visualization of Open-Heart Surgery

    Published on: August 12, 2021

    2.1K
    Author Spotlight: An Efficient and Robust Software for Automated Fusion of Multiple Preclinical Imaging Modalities
    07:13

    Author Spotlight: An Efficient and Robust Software for Automated Fusion of Multiple Preclinical Imaging Modalities

    Published on: October 27, 2023

    1.3K
    Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
    02:09

    Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function

    Published on: April 12, 2024

    676

    Area of Science:

    • Medical image analysis
    • Computer vision
    • Computational geometry

    Background:

    • Current non-rigid registration methods often rely on point-to-point or point-to-plane distances, leading to slow convergence and loss of anatomical detail.
    • These traditional metrics can struggle with accurate geometric approximation, hindering precise alignment in medical imaging.

    Purpose of the Study:

    • To develop a novel and robust non-rigid registration formulation for enhanced accuracy and efficiency.
    • To improve the approximation of underlying geometry during the registration process.

    Main Methods:

    • Proposed SPARE (Symmetrized Point-to-plane distance for Accurate Registration) utilizing a novel symmetrized point-to-plane distance metric.
    • Incorporated an as-rigid-as-possible regularization term for estimating deformed normals.
    • Employed an alternating minimization solver with a majorization-minimization strategy and deformation graph-based coarse alignment for initialization.

    Main Results:

    • The symmetrized point-to-plane distance, leveraging both positions and normals, provides a more accurate geometric approximation.
    • SPARE demonstrates significantly improved accuracy in non-rigid registration tasks compared to existing methods.
    • The method maintains high solution efficiency, validated through extensive experimental evaluations.

    Conclusions:

    • SPARE offers a superior approach to non-rigid registration, achieving higher accuracy through a refined distance metric.
    • The proposed optimization strategy and initialization enhance both the quality and efficiency of the registration process.
    • The publicly available code facilitates further research and application in medical image registration.