Related Experiment Video
Updated: May 3, 2026

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Precision in Practice: Clinical Indication-Specific DRLs for Head CT for Advanced Personalised Dose Benchmarking
Nora Almuqbil1, Zuhal Y Hamd1, Wiam Elshami2,3
1Department of Radiological Sciences, College of Health and Rehabilitation Sciences, Princess Nourah bint Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi Arabia.
Abstract:
Background/Objectives: Computed tomography (CT) of the head is vital in diagnosing neurological conditions but poses concerns regarding radiation exposure. Traditional diagnostic reference levels (DRLs) are based on anatomical regions, potentially overlooking variations in radiation requirements driven by clinical indication. This study aimed to establish clinical indication-specific DRLs (DRLCIs) for adult head CT to support precision benchmarking and optimise patient safety. Methods: A retrospective observational study was conducted using data from 378 adult patients undergoing non-contrast CT head scans between September 2022 and February 2024. Data on patient demographics, protocols, and radiation dose metrics (Computed Tomography Dose Index Volume and Dose-Length Product) were extracted using DoseWatch™ software. Protocol parameters were standardised across clinical indications such as trauma, stroke, headache, seizure, and infection. Descriptive statistics and correlation analyses were performed. Descriptive statistics, including means, standard deviations, and percentile distributions, were calculated. Correlation analyses were conducted using Pearson's correlation coefficient to examine relationships between dose metrics and patient variables such as age and body mass index. Results: Mean CTDIvol values ranged from 50.58 mGy (trauma) to 52.90 mGy (infection), while DLP values ranged from 1052.52 to 1219.98 mGy·cm. Percentile distributions were narrow, indicating effective protocol standardisation. The strongest correlation was observed between CTDIvol and DLP (r = 0.89), while age and body mass index showed negligible influence on dose metrics. Comparative analysis showed alignment with international benchmarks from the UK, Qatar, Bahrain, and Nigeria. Conclusions: This study establishes DRLCIs for adult head CT, demonstrating consistent radiation dose delivery across indications with minimal variability. Clinical indication-based benchmarking enhances dose optimisation and aligns with global radiological protection frameworks.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022