Related Experiment Video
Updated: Sep 11, 2025

Quantification of the Immunosuppressant Tacrolimus on Dried Blood Spots Using LC-MS/MS
Published on: November 8, 2015
Therapeutic Drug Monitoring of Everolimus Using Volumetric Absorptive Microsampling and Quantitative Dried Blood Spot
Arkadiusz Kocur1, Bartosz Olkowski2, Mateusz Moczulski1
1Department of Drug Chemistry, Pharmaceutical and Biomedical Analysis, Medical University of Warsaw, Banacha 1, 02-097 Warsaw, Poland.
Abstract:
Everolimus (EVE), an mTOR inhibitor, is widely used in solid organ transplantation (SOT) because of its immunosuppressive properties. Due to its narrow therapeutic window and significant pharmacokinetic variability, therapeutic drug monitoring (TDM) is essential for achieving optimal outcomes. We developed and thoroughly validated a robust LC-MS/MS method to measure EVE levels in venous whole blood (WB) and capillary blood collected using two microsampling devices: Mitra™ (volumetric absorptive microsampling, VAMS) and Capitainer® (quantitative dried blood spot, qDBS). The validation followed EMA and IATDMCT guidelines, assessing linearity (1.27-64.80 ng/mL for WB and 0.50-60 ng/mL for VAMS/qDBS), as well as selectivity, accuracy, precision, matrix effects, recovery, stability, and incurred sample reanalysis. Clinical validation involved 66 matched samples from 33 adult SOT recipients. The method demonstrated high accuracy and precision across all matrices, with no significant carryover or matrix interference. Statistical analysis using Passing-Bablok regression and Bland-Altman plots showed excellent agreement between the microsampling methods and the venous reference. Hematocrit effects were tested both in laboratory conditions and on clinical samples and were found to be negligible. This study provides the first comprehensive analytical and clinical validation of the Mitra and Capitainer devices for EVE monitoring. The validated LC-MS/MS microsampling method supports decentralized, patient-centred TDM, offering a reliable alternative to conventional blood sampling in transplant care.
More Related Videos
Related Concept Videos
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Drug Concentrations: Measurements
Plasma...

