Related Experiment Video
Updated: Sep 11, 2025

Laparoscopic Common Bile Duct Exploration in Patients with a Previous History of Biliary Tract Surgery
Published on: February 10, 2023
Contribution of the EyeMAX™ 11Fr (Micro-Tech) digital single-operator cholangioscope with a wide working channel: a
David Karsenti1, Adrien Sportes2, Sarah Leblanc3
1Digestive Endoscopy Unit, Pôle Digestif Paris Bercy, Clinique Paris-Bercy, 9 Quai de Bercy, Charenton-le-Pont 94220, France.
Background:
Digital single-operator cholangioscopy (DSOC) enhances biliary stricture diagnosis, but the collection of quality samples can be difficult due to the small diameter of the working channel.
Objectives:
A new DSOC system (EyeMAX™ 11Fr; Micro-Tech Endoscopy, Nanjing, China) with a 2.0-mm working channel, accommodating pediatric forceps (1.6 mm), has been introduced in France. This study reports on the first French experience.
Design:
A retrospective, multicenter observational study.
Methods:
The study on DSOC was conducted across five endoscopy units within the French Society of Private Hepato-Gastroenterology (SFHGL-CREGG). Satisfaction and procedural evaluations were recorded using a visual analog scale (VAS) and compared with the Spyglass™ DS II (Boston Scientific, Marlborough, MA, USA).
Results:
Among 28 patients, 71.5% had undergone prior endoscopic sphincterotomy. Indications were biliary strictures in 26 patients and lithiasis in 2. Strictures were located in the bile duct (41%) or hilum (59%). The mean satisfaction score was 8.69 out of 10, with the EyeMAX 11Fr rated as superior to the SpyGlass DS II in 86% of cases. The mean biopsy count was 8.52 in 13.19 min, with 100% procedural success. Pathology specimens were rich (24%), adequate (52%), low (12%), or absent (12%). Sensitivity for cholangiocarcinoma was 73.7% (14/19). Benign strictures regressed in all cases. Procedure-related complications included pain twice (7.1%), fever once (3.6%), infection once (3.6%), and pancreatitis twice (7.1%), all of which were resolved rapidly.
Conclusion:
This first study on the EyeMAX 11Fr DSOC highlights its ease of use, superior biopsy facilitation, and high user satisfaction, achieving 73.7% sensitivity for cholangiocarcinoma diagnosis.
Trial Registration:
ClinicalTrials.gov ID: NCT06933576.
Related Concept Videos
Endoscopic Procedures III: Video Capsule Endoscopy
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Endoscopic Procedures V: ERCP
Patient...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Endoscopic Procedures II: Colonoscopy