Effect of respiratory filter resistance on respiratory mechanics and human-machine synchrony during invasive jet
Zhenjie Jiang1, Zhili Zou2, Jiesen Zhang1
1Department of Critical Care Medicine, the First Affiliated Hospital of Guangzhou Medical University, Guangzhou, China.
Background:
To reduce the contamination of the breathing circuit, respiratory filters are used in patients receiving mechanical ventilation. However, their use increases the resistance and dead space volume of the breathing circuit, which potentially leads to asynchrony events, especially when patients are receiving jet nebulization. However, the impact of respiratory filter resistance on respiratory mechanics and human-machine synchronization during invasive ventilation with jet nebulization is not clear. Therefore, this study aims to investigate the question above and optimize the strategy of clinical filter using which may advance implementing lung-protective ventilation.
Methods:
The study carried out a self-controlled study and enrolled 12 patients receiving mechanical ventilation and monitored changes in respiratory mechanics and human-machine synchronization indicators under varying numbers of respiratory filters during jet nebulization.
Results:
The study found that jet nebulization, the use of respiratory filters and increasing filter resistance exacerbated abnormal triggering and asynchrony index [abnormal triggering: G1 vs. G2 vs. G3 vs. G4 (G1, G2, G3, and G4 represent baseline data, nebulization without filter data, nebulization with one filter data, and nebulization with two filters, respectively, hereinafter the same): 0.5 vs. 2.0 vs. 2.0 vs. 3.0 times/minute (P=0.01)]; [asynchrony index: 2.72% vs. 7.75% vs. 9.65% vs. 13.97% (P=0.01)]. Additionally, jet nebulization caused the increasing of inspiratory time/expiratory time (Ti/Te) [49.57% vs. 77.27% vs. 80.90% vs. 76.26% (P=0.02)].
Conclusions:
Increasing respiratory filter resistance during jet nebulization may exacerbate human-machine asynchronicity. Therefore, the use of filters during nebulization in invasive ventilation patients should be carefully considered, and filters should be replaced promptly after nebulization.
Related Concept Videos
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Mechanism of Breathing I: Inspiration
The respiratory system, an essential network for breathing, comprises the conducting and respiratory zones, each playing a crucial role in the overall process of respiration. Let us explore the detailed mechanism of inspiration, or inhalation, which is the first phase of the respiratory cycle.
Pathway of Air during Inspiration
During inspiration, air enters our body through the nose or mouth and moves through the conducting zone,...
Respiratory Volumes and Capacities I
Respiratory Volumes and Capacities