Multimodal Noninvasive Monitoring of Arterial Pressure: Do Limitations of Finger Cuff Monitoring Compromise Upper Arm
Karim Lakhal1, Jérôme E Dauvergne1,2, Grégoire Muller3,4,5
1Department of Anesthesia and Critical Care, Nantes Université, Laennec Hospital, CHU Nantes, University Hospital of Nantes, Nantes, France.
Objectives:
To assess the reliability of conventional automated oscillometric upper arm cuff (cuff ARM ): 1) when finger cuff monitoring (cuff FINGER ) of arterial pressure (AP) is suspected to be unreliable due to poor fingertip perfusion and/or hand edema or 2) fails to provide a reading.
Design:
Prospective observational study based on cohorts evaluating the CNAP (Dräger Medical) and ClearSight (Edwards Lifesciences) systems.
Setting:
Three ICUs.
Patients:
Adults with an arterial catheter and stable AP.
Interventions:
Three sets of triplicate AP measurements-simultaneous readings from the cuff FINGER , cuff ARM and, as a reference, arterial catheter-were collected for each patient.
Measurements And Main Results:
We analyzed 352 patients: 214 with the CNAP and 138 with the ClearSight cuff FINGER . In the 102 patients (29%) with poor fingertip perfusion-defined as a capillary refill time greater than 4 seconds-and/or hand edema, cuff ARM mean AP measurements ( n = 304) never failed, met the International Organization for Standardization (ISO) 81060-2:2018 standard (bias ± sd : 2.2 ± 7.2 mm Hg), posed no or low risk of harm in 99.7% of cases, and demonstrated good ability to detect hypotension and hypertension (area under the receiver operating characteristic curve, 0.91 [95% CI, 0.87-0.94] and 0.92 [95% CI, 0.75-1], respectively). In these 102 patients, cuff FINGER failed to display a reading in 17 patients (17%), and if not, did not meet the ISO 81060-2:2018 standard. In 38 of 352 patients (11%) in whom the cuff FINGER failed to display an AP measurement, cuff ARM met the ISO 81060-2:2018 standard for mean AP (bias ± sd : 1.7 ± 7.1 mm Hg). In the absence of failure and risk factors for erroneous measurements, ClearSight met the ISO 81060-2:2018 standard for mean AP, unlike the CNAP system.
Conclusions:
In a multimodal, noninvasive strategy for AP monitoring, ClearSight cuff FINGER may be suitable as a first-line tool due to its continuous nature. When unreliable or unavailable, cuff ARM provides reliable measurements, effectively detects hypotension and hypertension, and poses no significant risk to the patient.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
08:42Ultrasound Assessment of Endothelial-Dependent Flow-Mediated Vasodilation of the Brachial Artery in Clinical Research
Published on: October 22, 2014
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)