Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
4-Dimensional Computed Tomography Angiography for capturing cardiac cycle-induced volume change of intracranial
Lotte B Stam1, Sabine M L Linden1, René Aquarius1
1Department of Neurosurgery, Radboud University Medical Center, Nijmegen, the Netherlands.
Background:
Several studies suggest 4-Dimensional Computed Tomography Angiography (4D CTA) to assess wall motion of intracranial aneurysms as an indicator of stability. However, capturing cardiac cycle-related motion may exceed limits of imaging techniques. The goal is to evaluate consistency of aneurysm volume change across three consecutive cardiac cycles.
Methods:
Eighteen adult patients with unruptured and untreated intracranial aneurysms were recruited at Radboud University Medical Center. Three cardiac cycles were captured on a wide detector CT system, using electrocardiogram-gated 4D CTA. To reduce the impact of movements, a rigid-body registration was employed. Aneurysms were manually segmented and a deformable registration algorithm was used to determine volume change. The amplitude of absolute volume change, relative volume change, derived mean diameter were determined. The Pearson correlation was calculated as a measure of volume change pattern similarity across cardiac cycles.
Results:
Three of eighteen subjects were excluded because of technical difficulties, resulting in fifteen subjects with seventeen aneurysms. Among the remaining aneurysms, the mean absolute maximum volume change was 13.7 ± 26.5 mm3, the mean relative maximum volume change was 3.49 ± 1.45 %, and the mean averaged maximum diameter change per cardiac cycle was 0.068 ± 0.025 mm. In two aneurysms, the volume change pattern was consistent across cardiac cycles, and a fall-and-rise pattern was observed.
Conclusion:
This study indicates low consistency in intracranial aneurysm volume change patterns across cardiac cycles, questioning the feasibility of current CT scanners in capturing volume changes. Future research should focus on higher-resolution imaging on alternative metrics like shape changes, to improve assessment of aneurysm wall motion.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
08:12A Volumetric Method for Quantification of Cerebral Vasospasm in a Murine Model of Subarachnoid Hemorrhage
Published on: July 28, 2018
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System IV: CMRI
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT