Temporal image compression in cardiac computed tomography: impact of temporal super resolution and noise reduction
Masatoshi Kondo1,2, Yuzo Yamasaki3, Atsushi Ueno4,5
1Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-Ku, Fukuoka, Japan. kondou.masatoshi.074@m.kyushu-u.ac.jp.
None:
Computed tomography (CT) is valuable for assessing left ventricular (LV) function. However, it leads to increased data storage demands and energy consumption. Temporal super resolution (TSR) has the potential to reduce temporal data size while preserving accuracy. This study aimed to determine the feasibility of using TSR for temporal image compression in LV functional analysis. The study included 20 patients who underwent retrospective electrocardiogram (ECG)-gated cardiac CT, from which 20 cardiac phases per patient were acquired. TSR was applied to temporally compressed image data sets, with and without noise reduction (NR), using two NR levels: weak (30%) and strong (70%). Five data sets-including the original uncompressed data and four compressed versions-were analyzed for LV function using fully automated software. Bland-Altman plots and Pearson correlation coefficients were used to assess measurement agreement and reliability. The correlations between the uncompressed and compressed data sets for LV end-systolic volumes (ESVs), end-diastolic volumes (EDVs), and ejection fractions (EFs) were strong (all r = 1.00, 95% CI = 1.00-1.00, all Ps < 0.0001). Bland-Altman analysis showed reduced bias in LV measurements when TSR was applied without NR, while bias increased when NR was applied at both levels. The limits of agreement (LOA) were narrower for EDV but remained wider for ESV and EF. TSR without NR reduced bias but failed to narrow LOA, with EF improving or unchanged in 35% of cases. While this level of consistency is limited, the findings suggest that TSR may preserve functional accuracy under certain conditions.
More Related Videos
12:15Tissue Preparation Techniques for Contrast-Enhanced Micro Computed Tomography Imaging of Large Mammalian Cardiac Models with Chronic Disease
Published on: February 8, 2022
11:09High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies III: Computed Tomography