Related Experiment Video
Updated: Sep 11, 2025

Identification of Rare Bacterial Pathogens by 16S rRNA Gene Sequencing and MALDI-TOF MS
Published on: July 11, 2016
Accuracy of two Sepsityper MALDI-TOF MS methods for bacterial identification in bloodstream infections in dogs,
Donatienne Castelain1, Jade Bokma1,2, Mathilde Laetitia Pas1
1Department of Internal Medicine, Reproduction and Population Medicine, Ghent University, Merelbeke, Belgium.
Abstract:
Accurate diagnosis of bloodstream infections is crucial for survival and antimicrobial de-escalation in veterinary medicine. Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry enables faster identification of bacteria in BSIs. This study aimed to compare diagnostic accuracy of two Sepsityper® methods (Rapid Sepsityper® and Sepsityper® Extraction) with conventional culture method for bacterial identification in clinical samples. Mean time-to-positivity and frequency of bacteria in BSIs were also determined. This diagnostic test study used bloodstream infection samples from 385 critically ill animals (121 dogs, 119 foals, and 145 calves) admitted to the Faculty of Veterinary Medicine, Ghent (October 2021-February 2024). Accuracy was compared using Bayesian latent class model with priors for sensitivity (99.9%) and specificity (96.0%) based on literature, and a prevalence of 26.0%.
Abstract:
Conventional culture method identified 173 bacteria with Escherichia coli (19.1%,33/173), Staphylococcus spp. (12.1%,21/173) and Streptococcus spp. (8.1%,14/173) being most common. Sensitivity of Rapid Sepsityper®, Sepsityper® Extraction, and conventional culture method was 62.1%, 86.1%, and 97.4%, respectively. Specificity was 94.3%, 90.4% and 92.3%, and accuracy was 85.8%, 89.3%, and 93.6%, respectively. Mean time-to-positivity and ±standard deviation for blood cultures flagging positive was 21h25min ±17.8h. Rapid Sepsityper® identified bacteria in approximately 30min, while Sepsityper® Extraction method required around 50min, and conventional culture method needed 12-48h. Altogether, Sepsityper® Extraction shows promise given the sensitivity and results were delivered more rapidly than conventional culture. Enhancing diagnostic workflow, resulting in a better prognosis, reduced hospital stays, and lower healthcare costs due to more rational use of (critically important) antimicrobials.
More Related Videos
Related Concept Videos
MALDI-TOF Mass Spectrometry
Matrix-assisted laser desorption ionization (MALDI) is a commonly...
Methods of Classification and Identification
Modern Molecular Taxonomy
Applications of Molecular Taxonomy