Related Experiment Video
Updated: Sep 11, 2025

A Vibrotactile Feedback Device for Seated Balance Assessment and Training
Published on: January 20, 2019
[Design and application of a chest belt-type vibration expectorator]
Yan Xu1, Chengcheng He2, Wenzhe Li1
1Department of Critical Care Medicine, Ruijin Hospital, Shanghai Jiao Tong University, Shanghai 200025, China.
Abstract:
Disruption of normal secretion or mucociliary clearance can impair airway defense mechanisms and lung function, and increase the risk of infection. Airway clearance techniques are recommended as part of a comprehensive treatment plan for patients. Among these, vibratory expectoration is an important method of airway clearance, which loosens and liquefies mucus and metabolites on the surface of the respiratory tract through chest wall oscillation, promoting ciliary movement to facilitate sputum expulsion. However, commonly used handheld vibrating head devices and vest-type vibration expectorators have several limitations in clinical practice, such as inconvenience of operation, limited treatment time, poor adaptability, and difficulty in disinfection. To address these issues, the research team from the department of critical care medicine at Ruijin Hospital, Shanghai Jiao Tong University, has designed a novel belt-type vibration expectorator, which has been granted a national utility model patent (Patent No.: ZL 2023 2 1610983.1). The device is mainly composed of a chest strap assembly, a sputum clearance component, and a fixed shoulder strap component. Several pockets are placed on the outer surface of the chest strap, with corresponding inner-side openings that allow the percussion head of the percussive expectorator placed inside the pocket to make contact with the patient's chest wall. Each pocket has markings indicating the percussion position, enabling the placement of the percussive expectorator according to the location of infection, thereby achieving multi-point, precise percussive vibration expectoration in different body positions. On the inner side of the chest strap, there are diagrams illustrating postural drainage, providing guidance on the body positions patients should assume based on the location of infection. The hook-and-loop fasteners on both sides of the chest strap can be wrapped around and secured according to the patient's body shape, ensuring that the sputum clearance components adhere tightly to the chest wall, allowing the vibrations generated by percussion to be effectively transmitted to the patient's airways. Additionally, to prevent the chest strap from slipping due to changes in the patient's position, a Y-shaped fixing strap can be selectively attached to the chest strap for further stabilization. This innovation not only simplifies the operation process, improves convenience and flexibility of use, but also supports the principle of "disinfection after each use by one person," which helps to reduce the risk of nosocomial infections and improve the efficiency of patients' respiratory rehabilitation.
Related Concept Videos
Chest Physiotherapy
Purpose
CPT is primarily used for patients with excessive bronchial secretions who have difficulty clearing...
Flail Chest-II
Assessment:
1. Clinical Evaluation:
History:
Cardiopulmonary Resuscitation II: ACLS Airway Management
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Suctioning the Nasopharyngeal Airway
Equipment Required