Related Experiment Video
Updated: Sep 11, 2025

Characteristics of Precipitation-formed Polyethylene Glycol Microgels Are Controlled by Molecular Weight of Reactants
Published on: December 23, 2013
The Use of Monodisperse Poly(propylene glycol)‑8 as a Polymeric Additive: Effect on the Gelation Temperature and
Zuzanna Samol1,2, Erik Agner2, Magne O Sydnes1,3
1Department of Chemistry, Bioscience, and Environmental Engineering, University of Stavanger, Stavanger 4036, Norway.
Abstract:
Pluronic F127 is widely used for hydrogel preparation, but its low gelation temperature (21 °C at a concentration of 25 wt %) and limited ability to deliver hydrophobic drugs hinder medical applications. A standard approach to address these limitations involves combining Pluronic F127 with other polydisperse polymers, further increasing the system complexity. This study demonstrates the use of monodisperse and high-purity poly-(propylene glycol)-8 (PPG-8), obtained via cost-effective chromatographic purification, as a polymeric modifier. The effect of PPG-8 addition to Pluronic F127, varying from 5 to 20 parts (w/w), was assessed via the vial tilt method and oscillatory rheology. The incorporation of PPG-8 increased the gelation temperature from 21 to 31 °C. The impact of PPG-8 addition on the release of small hydrophilic and hydrophobic molecules was also studied. In the presence of PPG-8, the cumulative release of a hydrophobic small molecule increased from 20% to 60%. Contrastingly, the initial burst release of a small hydrophilic molecule was reduced from 81% to 56% in the first 10 min. These findings showcase the use of high-purity modifiers such as PPG-8 to fine-tune the properties of Pluronic hydrogels, enabling more reproducible formulations for potential clinical use.
More Related Videos
15:33Microwave-assisted Functionalization of Polyethylene glycol and On-resin Peptides for Use in Chain Polymerizations and Hydrogel Formation
Published on: October 29, 2013
12:07Fabricating Degradable Thermoresponsive Hydrogels on Multiple Length Scales via Reactive Extrusion, Microfluidics, Self-assembly, and Electrospinning
Published on: April 16, 2018
Related Concept Videos
Polymer Classification: Stereospecificity
Molecular Weight of Step-Growth Polymers
As the step-growth polymerization involves step-wise condensation of monomers, the molecular weight also builds up eventually. Consequently, high molecular weight polymers are obtained at the late stages of the polymerization, where 99% of monomers have been consumed.
The extent of the...
Polymers: Molecular Weight Distribution