Background:
Valve regurgitation is associated with systemic ventricular dysfunction and mortality in patients with Fontan palliation. Valve repair and valve replacement with bioprostheses have limited durability, and outcomes after valve replacement with mechanical prostheses are poorly defined. The study objectives were to assess: (1) Operative mortality, valve-related complications (stroke, mechanical valve thrombosis, major bleeding complication, prosthetic valve endocarditis, and valve reoperation), and late mortality/transplant. (2) Postoperative changes in ventricular volumes and ejection fraction; (3) Postoperative changes in the clinical indices of disease severity.
Method:
Retrospective cohort study of adults (age ≥18 years) with Fontan palliation who underwent isolated aortic or atrioventricular valve replacement at Mayo Clinic (2003-2023). Preoperative and postoperative evaluations (clinical evaluation, echocardiogram, biomarkers) were performed 6 months preoperatively and 6-24 months postoperatively, respectively.
Results:
Overall, 17 patients underwent isolated atrioventricular (N = 9) or aortic valve (N = 8) replacement with mechanical prosthesis (age 27 ± 8 years; 9 [53 %] males). There was no operative mortality. There was postoperative improvement in functional capacity (NYHA class), heart failure indices (NT proBNP), and hepatorenal function (MELD-XI score). There was a postoperative decrease in systemic ventricular volumes, without change in ejection fraction. The 10-year cumulative incidence of valve-related complications and death/transplant was 15 % and 18 %, respectively.
Conclusions:
Atrioventricular valve and aortic valve replacement with mechanical prostheses was associated with low (zero) operative mortality, low risk of valve-related complications, and clinical improvement. This suggests that valve replacement with mechanical prostheses may be an effective palliation in selected patients and may delay the need for transplant in this population.
More Related Videos
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
14:14Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
Related Concept Videos
Mitral Stenosis III: Medical Management
Mitral Regurgitation III: Medical Management
Aortic Regurgitation III: Medical Management
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Mitral Stenosis I: Introduction
Mitral Stenosis IV: Nursing Management