Related Experiment Video
Updated: Jul 28, 2026

Proximal Cadaveric Femur Preparation for Fracture Strength Testing and Quantitative CT-based Finite Element Analysis
Published on: March 11, 2017
[Anatomically adapted endoprosthesis of the proximal end of the femur]
Abstract:
The marrow-cavities of several human femora were cleaned and filled with plastics; the femoral component design was developed based on these moulds. Different sizes of the stem were obtained by scaling down the biggest mould in steps of 10%. The stem has an oval cross-section and is twisted similar to the form of the marrow-cavity; therefore different designs for the left and right femur are necessary. As the marrow-cavity of the femur tapers down to the middle of the shaft the length of the prosthetic stem cannot be selected arbitrarily. The stem must end above the narrowest site of the cavity. Data are presented. To avoid disadvantageous frictional stresses between the collar of the prosthesis and the plane of resection of the femoral neck both must be aligned perpendicular to the most common direction of the load of the hip joint. Therefore a step-like osteotomy of the femoral neck becomes necessary without disturbing the calcar femorale instead of an inclined osteotomy. A firm contact between the femoral wall and the collar, which forms an angle of 64 degrees with the axis of the femoral shaft, guarantees that only small frictional stresses occur between collar and femoral cortex if the load of the hip joint varies within the physiological range. A set of ceramic femoral heads with three different conical borings yield different lengths of the neck of the prosthesis. Independent of which femoral head and which size of prosthesis are chosen the direction of the maximum hip load in any case thrusts the contact area between collar and femoral wall. Thus dangerous tilting moments round the medial calcar femorale do not occur, the incidence of a fracture of the prosthesis shaft is therefore reduced. After implantation of the anatomically designed femoral component both remodeling and resorption of the calcar femorale are observed. This reaction is independent of the kind of fixation, i.e. if a smooth stem was fixed with cement or a stem with a porous, cancellous bone-like metallic surface was implanted without cement fixation.(ABSTRACT TRUNCATED AT 250 WORDS)
More Related Videos
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
07:33In Vitro Application of a Wireless Sensor in Flexion-Extension Gap Balance of Unicompartmental Knee Arthroplasty
Published on: May 5, 2023
Related Concept Videos
Bones of the Upper Limb: Humerus
Bones of the Lower Limb: Femur and Patella
Bones of the Lower Limb: Tibia and Fibula
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris group...