Related Experiment Video
Updated: May 1, 2026

Nerve Stimulator-guided Injection of Autologous Stem Cells Near the Equine Left Recurrent Laryngeal Nerve
Published on: September 26, 2018
Validation of an Endoscopic Landmark for Injection of Internal Branch of Superior Laryngeal Nerve
Yuki Tanigami1, David Hortobagyi2, Andrew J Bowen3
1Division of Otolaryngology-Head and Neck Surgery, Department of Surgery, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA.
Objective:
This study aims to validate a novel transnasal endoscopic approach for accurately targeting the internal branch of the superior laryngeal nerve (iSLN) via the piriform sinus, with the goal of improving treatment outcomes for laryngeal sensory dysfunction (LSD).
Methods:
Eight cadaveric larynges were examined using a 3D-printed cadaveric laryngeal model. The superolateral quadrant of the piriform sinus was endoscopically marked with toluidine blue ink. The distance between the ink mark and the iSLN confluence point was measured as well as other landmarks.
Results:
The mean distance from the ink to the iSLN confluence was 5.38 mm, with significantly less variability than traditional external landmarks.
Conclusion:
The transnasal approach provides a reliable, anatomically precise method for accessing the iSLN, offering potential advantages over traditional external techniques in the management of LSD.