Are single-lead consumer ECG devices enough for accurate QTc monitoring? A calibrated uncertainty AI approach
Peter Doggart1, Raymond Bond2, Dewar Finlay2
1PulseAI Ltd., Belfast, UK; Ulster University, Belfast, UK.
Background:
While single‑lead ECGs offer accessibility, their performance and reliability for QTc assessment remains uncertain. Current State-of-the-art AI systems, though promising, often lack transparency, raising concerns about clinical trustworthiness.
Methods:
We developed an uncertainty-aware AI model to measure RR/QT intervals from single‑lead ECGs. Training used retrospective datasets (∼400,000 ECGs) from clinical 12‑lead systems, with testing on 2050 manually annotated AliveCor KardiaMobile single‑lead (lead-I) ECGs. QTc Fridericia values were calculated using a first-order approximation and delta method for uncertainty propagation. Performance was evaluated using (1) Bland-Altman analysis and uncertainty calibration (ENCE), (2) Classification performance for QTc prolongation at 450/470/500 ms thresholds using probabilistic outputs and area under the receiver operator curve (AUROC) and (3) QT nomograms for risk visualization.
Results:
The model demonstrated strong QTc estimation performance with integrated uncertainty quantification. After excluding 11 % of ECGs flagged as unreliable through uncertainty analysis, the remaining 89 % showed excellent agreement with 12‑lead reference values (mean bias: -0.7 ms, limits of agreement: -42 to +41 ms). The excluded high-uncertainty cases exhibited substantially larger errors (mean bias: 15.3 ms, limits of agreement: -104 to +134 ms). Uncertainty estimates were well-calibrated (ENCE: 14.6 %), enabling effective identification of unreliable predictions for expert review while maintaining clinical-grade accuracy in retained cases. Classification achieved excellent AUROCs in low-uncertainty cases: 0.87 [95 % CI: 0.85-0.89](≥450 ms), 0.90 [95 % CI: 0.86-0.93](≥470 ms), 0.96 [95 % CI: 0.92-1.00](≥500 ms).
Conclusions:
By integrating uncertainty quantification, this AI model enables trustworthy QTc monitoring using single‑lead ECGs, dynamically flagging unreliable measurements. This approach enhances clinical safety and expands access to cardiac risk assessment in remote settings. The methodology sets a precedent for developing transparent, reliable AI tools in healthcare, prioritizing trust over traditional explainability.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Holter Monitor: 24-Hour Monitoring
Dysrhythmias V: Evaluating Dysrhythmias
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...