Related Experiment Video
Updated: Sep 10, 2025

Clean Sampling and Analysis of River and Estuarine Waters for Trace Metal Studies
Published on: July 1, 2016
A rapid method for detecting trace Rb and Cs in high-salinity brines by ICP-MS equipped with an all-matrix sampling
Xiuzhen Ma1,2, Xin Liu1, Zhe Ma3
1Key Laboratory of Green and High-end Utilization of Salt Lake Resources, Qinghai Institute of Salt Lakes, Chinese Academy of Sciences, Xining, 810008, People's Republic of China.
None:
This study presents a rapid and highly sensitive method for the determination of trace rubidium (Rb) and cesium (Cs) in high-salinity brines using inductively coupled plasma mass spectrometry (ICP-MS) equipped with an all-matrix sampling (AMS) device. The AMS system achieves online gas dilution by vertically introducing argon gas into the brine sample flow, effectively reducing the severe matrix suppression effect caused by 35 g·L-1 salinity to an intermediate level. Experimental results demonstrated that the signal suppression induced by coexisting cations (K+, Na+, Ca2+, Mg2+) in actual brine samples was minimal (< 1.5%), thereby eliminating the need for conventional matrix matching or standard addition approaches. Accurate quantification was achieved through a straightforward calibration process based on standard curves (Rb: 5-400 μg·L-1; Cs: 5-400 μg·L-1; R2 > 0.999), enhanced by dynamic internal standard correction using yttrium (Y) and rhodium (Rh), along with optimized instrument parameters (RF power and nebulizer gas flow rate). The method demonstrates excellent limits of detection (LOD: 0.039 μg·L-1 for Rb; 0.005 μg·L-1 for Cs), high precision (RSD < 5%), and acceptable recovery rates (85%-108%). The accuracy was further validated through comparison with AAS standard addition for high-concentration samples (> 200 μg·L-1), yielding consistent recoveries (98.6% -114%) and inter-method deviations ≤ 12.2%. Additionally, the simplification of the sample pretreatment procedure-from a traditional multi-step dilution to a single-step dilution without acid-washed containers-enhances analytical efficiency by over 70%. This approach provides a robust, sensitive, and operationally efficient solution for the analysis of extreme high-salinity environmental samples.
More Related Videos
08:53Automated 90Sr Separation and Preconcentration in a Lab-on-Valve System at Ppq Level
Published on: June 6, 2018
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
High-Performance Liquid Chromatography: Types of Detectors