Related Experiment Video
Updated: Sep 8, 2025

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
Published on: August 30, 2013
Optimized bio-signal reconstruction and watermarking via enhanced fractional orthogonal moments
Gaber Hassan1, Khalid M Hosny2, Islam S Fathi3
1Department of Computer Science, Faculty of computers and information, Arish University, Al-Arish, 45511, Egypt. gh_mcs86@yahoo.com.
Abstract:
Orthogonal Tchebichef moments of fractional order (FrTMs) serve as descriptors for signals and images. Many fields, including signal analysis and watermarking, have relied heavily on such moments. This study addresses three critical limitations in existing approaches: the computational burden of higher-order moment calculations, numerical instability affecting reconstruction accuracy, and orthogonality deterioration in large-scale signal processing. Furthermore, using the QR decomposition approach is crucial to maintain the orthogonality of the higher-order moments. We introduce an improved computational framework with three main scientific contributions as development of an optimized set of three interrelated second-order recurrence equations for normalized FrTMs, implementation of the Schwarz-Rutishauser algorithm as an alternative to classical QR decomposition methods, maintaining orthogonality with substantially lower computational overhead; and integration of these innovations into a comprehensive system for biomedical signal reconstruction and watermarking. The method in question was tested on two benchmark datasets the MIT-BIH arrhythmia and CHB-MIT Scalp EEG. The findings indicate that the proposed methodology exhibits significantly higher performance levels than current methodologies, with a 64.3% improvement in PSNR (reaching 147.08 dB compared to 89.74 dB in existing approaches), 89.7% reduction in MSE (0.0092 versus 0.09 average), and 84.1% decrease in bit error rate (0.25 versus 1.57) for watermarking applications. Processing time was also reduced by 64.3% compared to competing methods, making this approach substantially more efficient for implementation in Internet of Healthcare Things (IoHT) contexts.
Related Concept Videos
Reconstruction of Signal using Interpolation
Aliasing
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
Upsampling
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
Even and Odd Signals